Parker Hannifin S.p.A. - S.B.C. Division HPD N User’s Manual
87
5.2.
Serial addresses and parameter lengths
Parameter
Address Length Meaning
Pr0
038h
2
motor speed in rpm
Pr1
034h
2
analogue
reference
Pr2
03Ah
2
full
scale
1
Pr3
03Ch
2
full
scale
2
Pr4
036h
2
frequency full scale
Pr5
03Eh
2
internal
reference
Pr6
040h
2
reserved
reference
Pr7
042h
2
chosen
reference
Pr8
0AEh
2
positive
acceleration
in
seconds
Pr9
0B0h
2
positive
deceleration
in
seconds
Pr10
0B2h
2
negative
acceleration
in
seconds
Pr11
0B4h
2
negative
deceleration
in
seconds
Pr12
0B6h
2
limit
switch
deceleration
Pr13
0B8h
2
overspeed
threshold
Pr14
044h
2
top
speed
limit
Pr15
046h
2
lower
speed
limit
Pr16
048h
2
integral
gain
Pr17
0BAh
2
damping
factor
Pr18
0BCh
2
filter
time
constant
Pr19
0BEh
2
user
current
limit
Pr20
04Ah
2
DC bus voltage
Pr21
04Ch
2
reserved torque limit
Pr22
04Eh
2
auxiliary
reference
Pr23
051h
1
current
alarm
code
Pr24
052h
1
previous
alarm
code
Pr25
053h
1
software
version
code
Pr26
05Eh
1
baud
rate
Pr27
05Fh
1
serial
address
Pr28
0C0h
2
shaft position (0..4095)
Pr29
061h
1
motor
poles
Pr30
0C2h
2
resolver
offset
Pr31
054h
1
operating
mode
Pr32
0C4h
2
rated
motor
speed
Pr33
0C6h
2
rated
current
Pr34
055h
1
scale factor for tacho generator
Pr35
0C8h
2
filtered torque request
Pr36
058h
2
i
2
t accumulation
Pr37
05Ah
2
thermal image for braking
Pr38
0CAh
2
auxiliary analogue output
Pr39
0CCh
2
K for phase advance
Pb40
05Ch
2
flags used by main block
Содержание HPD2N