26
The principal parameter units and resolutions are:
4.1.
Using the keypad
The keypad-display module is designed to provide an intuitive operator interface. It can be
used to program operating data, monitor system status and enter commands.
The module has only three keys, located at the top of the front panel just below the
display. The keys are marked: [M], [+] and [-].
[M] is used to change the display mode and consequently also the function of [+] and [-].
There are two display modes: parameter mode and parameter value mode.
When the unit is powered up, provided there are no active alarms, the message “IdLE”
(drive disabled) or “run” (drive enabled) is displayed; this is also the position of parameter
Pr0.
Press [+] or [-] to scroll through the parameters.
If you want to check a parameter value, press [M]; when the value is shown it can be
updated using [+] and [-].
To return to parameter mode press [M] again.
The display can be shown in various forms, depending on the parameter in question.
If you need to increase (or decrease) a parameter value quickly, press [M] while the up key
[+] (or down key [-] ) is pressed.
M
Pr. 01
Pb. 40
+
-
+
-
Pr. 02
+
-
In. 00
In. XX
+
-
M
XXXXX
M
M
XXXXX
+
-
+ 1
+ 9
M
- 1
- 9
M
M
M
XXXXX
+
-
+ 1
+ 9
M
- 1
- 9
M
M
M
b40.XX
+
-
1
0
M
M
XX
+
done
M
PLC inst.
M
+
-
1st oper.
M
+
-
2nd oper.
M
+
-
3rd oper.
M
+
-
HPD keypad
Pb. 99
M
XX
+
-
b99.XX
M
+
-
IDLE
parameter unit resolution
speed revolutions
per
minute
1
acceleration
seconds / 1000 rpm.
0.001
position
4096 steps / revolution
1/4096 revolution
current
% of the drive peak current
0.1