Chapter 1. Installation
37
3. Verify that the Active Damping Rotary Switch is at Zero
4. Calculate the Maximum Rotary Switch Setting
To do this, first calculate your system inertia. Be sure to include the motor's rotor inertia. Then
consult the table of inertia ranges below. Find the switch setting that corresponds to your system
inertia.
DIP SW2-#6 in OFF Position (Low Inertia Range)
Switch
Position
Total Inertia
(kg-cm
2
)
Total Inertia
(kg-m
2
x 10
-6
)
Total Inertia
(oz-in
2
)
15
14
13
12
11
0.088 - 0.205
0.205 - 0.572
0.572 - 1.069
1.069 - 1.754
1.754 - 2.727
8.8 - 20.5
20.5 - 57.2
57.2 - 106.9
106.9 - 175.4
175.4 - 272.7
0.481 - 1.121
1.121 - 3.127
3.127 - 5.845
5.845 - 9.590
9.590 - 14.910
10
9
8
7
6
2.727 - 3.715
3.715 - 5.020
5.020 - 6.275
6.275 - 8.045
8.045 - 9.595
272.7 - 371.5
371.5 - 502.0
502.0 - 627.5
627.5 - 804.5
804.5 - 959.5
14.910 - 20.312
20.312 - 27.447
27.447 - 34.308
34.308 - 43.986
43.986 - 52.460
5
4
3
2
1
9.595 - 11.760
11.760 - 14.245
14.245 - 15.895
15.895 - 17.765
17.765 - 20.570
959.5 - 1176.0
1176.0 - 1424.5
1424.5 - 1589.5
1589.5 - 1776.5
1776.5 - 2057.0
52.460 - 64.297
64.297 - 77.884
77.884 - 86.905
86.905 - 97.130
97.130 - 112.466
0 Active Damping Disabled
DIP SW2-#6 in ON Position (High Inertia Range)
Switch
Position
Total Inertia
(kg-cm
2
)
Total Inertia
(kg-m
2
x 10
-6
)
Total Inertia
(oz-in
2
)
15
14
13
12
11
13 - 31
31 - 86
86 - 161
161 - 264
264 - 410
1324 - 3084
3084 - 8606
8606 - 16084
16084 - 26390
26390 - 41029
75 - 169
169 - 471
471 - 879
879 - 1443
1443 - 2243
10
9
8
7
6
410 - 559
559 - 755
755 - 944
944 - 1210
1210 - 1444
41029 - 55894
55894 - 75528
75528 - 94411
94411 - 121041
121041 - 144362
2243 - 3056
3056 - 4129
4129 - 5162
5162 - 6618
6618 - 7893
5
4
3
2
1
1444 - 1769
1769 - 2143
2143 - 2391
2391 - 2673
2673 - 3095
144362 - 176935
176935 - 214323
214323 - 239148
239148 - 267283
267283 - 309486
7893 - 9674
9674 - 11718
11718 - 13075
13075 - 14614
14614 - 16921
0 Active Damping Disabled
Active Damping Rotary Switch Settings & Corresponding Inertia Ranges
This is your Maximum switch setting. If you are on the boundary between two switch settings, pick
the lower of the two numbers. In the rest of this procedure never set the switch higher than this
maximum setting.
5. Make a Move With Active Damping Turned Off
(Rotary switch should be in the zero position.) This is your baseline move. Notice the sound, amount
of motor vibration, etc. This move shows how your system operates with anti-resonance enabled, and
active damping disables. Each time you adjust this switch, you will compare results with this baseline
move.
The move should be representative of your application, with similar velocity and acceleration. The
speed must be faster than 3 rps, in order for the drive to activate anti-resonance or active damping.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com