Operating Instructions
COMPAX-M / -S
PLC data interface (function not available with COMPAX 1000SL)
158
Start sign
"E"
≡
"1110"
Function code 1: "1"
≡
"0001"
Function code 2: "3"
≡
"0011"
Parameter No. tens column
Parameter No. digits column
Assignment code: "A"
≡
"1010"
Sign "0"
≡
"0000": positive
"D"
≡
"1101": negative
Numerical value 10
6
Numerical value 10
5
Numerical value 10
4
Numerical value 10
3
Numerical value 10
2
Numerical value 10
1
Numerical value 10
0
Decimal point
"C"
≡
"1100"
Numerical value 10
-1
Numerical value 10
-2
End sign
"F"
≡
"1111"
Start sign
"E"
≡
"1110"
Function code 1: "1"
≡
"0001"
Function code 2: "4"
≡
"0100"
End sign
"F"
≡
"1111"
Start sign
"E"
≡
"1110"
Function code 1: "1"
≡
"0001"
Function code 2: "6"
≡
"0110"
Numerical value 10
1
Numerical value 10
0
End sign
"F"
≡
"1111"
Start sign
"E"
≡
"1110"
Sign "0"
≡
"0000": positive
"D"
≡
"1101": negative
Numerical value 10
6
Numerical value 10
5
Numerical value 10
4
Numerical value 10
3
Numerical value 10
2
Numerical value 10
1
Numerical value 10
0
Decimal point
"C"
≡
"1100"
Numerical value 10
-1
Numerical value 10
-2
Numerical value 10
-3
End sign
"F"
≡
"1111"
The following signs are not necessary when transferring:
♦
Positive prefixes and initial zeros.
♦
For whole number values: the decimal point and the figures after the decimal
point.
Modify
parameters
P1...P49
Acceptance of VP
parameter
Status query
S1...S12 (actual
values)
Status response
S1...S12 (actual
values)