6-14
Programming Your Application
650S AC Drive
MMI Parameters Table
Display
Parameter
Description
Range
Default
SET::PAC1 Menu
MAX SPEED MOTOR1
M
Set the maximum motor 1 speed.
0 to 30000 RPM
3200RPM
MAX CURRENT
MOTOR1
M
Set the motor 1 maximum current in Amps rms.
1.0 to 512.0 Arms
5.65A
PERM CURRENT
MOTOR1
M
Set the motor 1nominal current in Amps rms.
1.0 to 512.0 Arms
2.43A
PERM TORQUE
MOTOR1
M
Set the motor 1 nominal torque in Nm.
1.0 to 512.0 Nm
2.0Nm
POLES
MOTOR1
M
Set the motor 1 number of poles.
0 to 400
10
BACK EMF MOTOR1
M
Set the motor1’s Back EMF phase to phase, rms value (in
Volts/1000RPM)
0 to 8192
Vrms/1000RPM
50.9V
R
MOTOR1
M
Set the motor1’s resistance, between phase at 25°C.
0 to 50 Ohms
6.58Ohms
L
MOTOR1
M
Set the motor1’s inductance, between phase at nominal current.
0 to 1000mH
20.3mH
KT
MOTOR1
M
Set the motor1’s torque constant in Nm/Amps rms
0 to 100 NM/Arms
0.848NM/
A
INERTIA
MOTOR1
M
Set the motor1’s inertia. The units for this parameter are set by the
INERTIA SCALE parameter.
0 to 100
0.070
INERTIA SCALE
MOTOR1
M
Set the motor1’s inertia scale:
0 = gm²
1 = kgcm²
2 = kgm²
0
Содержание 650S Series
Страница 1: ...650S 650S P P Pr r ro o od d du u uc c ct t t M M Ma a an n nu u ua a al l l HA500924U001 S E R I E S ...
Страница 9: ...Cont 8 ...
Страница 13: ...1 4 Getting Started 650S AC Drive ...
Страница 39: ...4 8 Operating the Drive 650S AC Drive ...
Страница 101: ...8 4 Routine Maintenance and Repair 650S AC Drive ...
Страница 127: ...10 10 Certification for the Drive 650S AC Drive ...
Страница 128: ...Serial Communications 11 1 650S AC Drive Chapter 11 Serial Communications Connection to the P3 Port 11 2 ...