6-10
Programming Your Application
650S AC Drive
MMI Parameters Table
Display
Parameter
Description
Range
Default
BAUD RATE
F
Selects the Baud Rate for the MODBUS protocol.
0 : 1200
1 : 2400
2 : 4800
3 : 7200
4 : 9600
5 : 14400
6 : 19200
7 : 38400
8 : 57600
4
PARITY
F
Selects the Parity for the MODBUS protocol.
0= NONE
1= ODD
2= EVEN
0
REPLY DELAY ms
The time in milliseconds between the drive receiving the complete
request from the communications master (PLC/PC) and replying to this
request.
0 to 200
5
OP PORT
PROTOCOL
F
Selects the protocol to be used by the keypad port on the front of the
drive. When EIBISYNC ASCII is selected, BAUD RATE is 19200 and
PARITY is EVEN. FIELDBUS is reserved for future use.
0= AUTOMATIC
1= KEYPAD
2=EIBISYNC ASCII
3= MODBUS
4= FIELDBUS
0
P3 PORT PROTOCOL
F
Selects the protocol to be used by the RS232 programming port on the
drive's control board. When EIBISYNC ASCII is selected, BAUD RATE is
19200 and PARITY is EVEN. FIELDBUS is reserved for future use.
As
S
SE07 0
SET::SETP Menu
JOG ACCEL TIME
As
P
4, for Jog
0.0 to 3000.0s
1.0
JOG DECEL TIME
As
P
5, for Jog
0.0 to 3000.0s
1.0
RAMP TYPE
Selects the ramp type
0=LINEAR
1=S
0
S RAMP JERK
Rate of change of acceleration of the curve in units per second³
0.01 to 100.00 s3
10.00
S RAMP
CONTINUOUS
When TRUE and the S ramp is selected, forces a smooth transition if the
speed setpoint is changed when ramping. The curve is controlled by the
S RAMP JERK parameter. When FALSE, there is an immediate transition
from the old curve to the new curve
0=FALSE
1=TRUE
1
MIN SPEED MODE
Selects a mode to determine how the drive will follow a reference:
Proportional : minimum limit, Linear : between minimum and maximum.
0=PROP.W/MIN.
1=LINEAR (used by
the 601 product)
0
SKIP FREQUENCY 1 This parameter contains the centre frequency of skip band 1 in Hz
0.0 to 240.0 Hz
0.0
Содержание 650S Series
Страница 1: ...650S 650S P P Pr r ro o od d du u uc c ct t t M M Ma a an n nu u ua a al l l HA500924U001 S E R I E S ...
Страница 9: ...Cont 8 ...
Страница 13: ...1 4 Getting Started 650S AC Drive ...
Страница 39: ...4 8 Operating the Drive 650S AC Drive ...
Страница 101: ...8 4 Routine Maintenance and Repair 650S AC Drive ...
Страница 127: ...10 10 Certification for the Drive 650S AC Drive ...
Страница 128: ...Serial Communications 11 1 650S AC Drive Chapter 11 Serial Communications Connection to the P3 Port 11 2 ...