background image

  SAFETY PRECAUTIONS 

5

 

WARNING

J

 

Be careful not to get your body caught. 

z

 

When used together with a bed side-rail or swing
arm bed grip/side support, your body may get
caught in the gap between those products or bed
and the air mattress and you may be injured or
suffocated due to the pressure. Special attention is
required because this product easily sinks because
of its characteristics.

J

 

Take care to prevent the drain tube from getting 
caught. 

z

 

Take care to prevent the drain tube from getting
caught in the gap between the air mattress, bed,
and a bed-side rail or swing arm bed grip. The drain
tube could come off or be smashed.

J

 

Do not operate the operation panel with part of 
the body placed in the gap between the bed 
and a bed-side rail, etc. 

z

 

The body part may get caught in the gap, possibly
causing injury.

z

 

Be especially careful to check users who might act
in unexpected ways or cannot maintain their
posture independently.

J

 

For the bed or other products used in 
combination with the air mattress, use suitable 
products specified by Paramount Bed. 

z

 

The use of products other than the specified

suitable products or products from other companies
could create unintended gaps, cause interference
between products, or lower stability, resulting in
injury or damage to the air mattress. For suitable
products, see p. 

30

.

J

 

Do not use the air mattress for infants or 
children

  aged 1  or under

z

 

This product is not designed for infants or children.
There is a risk of injury or suffocation due to
pressure caused by a part of the body getting
caught in the gap between the air mattress and a
bed side-rail, etc.

J

 

Use an air mattress that is the same width and 
length as the bed. 

z

 

If an air mattress that is not the same width and
length as the bed is used, there is a risk of
unexpected gaps being created and part of the
body getting caught, resulting in injury.

J

 

When getting in and out of the bed (air 
mattress) or taking a sitting position, be careful 
not to fall or topple over. 

z

 

When getting in and out of the bed (air mattress) or

taking a sitting position, set "Max inflate mode" and
wait  for  the  air  mattress  to  become  hard  before
doing  it.  Furthermore,  a  caregiver  or  attendant
should support the body of the user or let the user
hold  on  to  the  swing  arm  grip,  etc.  to  ensure  that
the user does not slip off the bed.

J

 

Take care to prevent the user from falling off 
the bed even when bed side-rails are used. 

z

 

The user may bend forward over a bed side-rail
and fall off the bed, possibly causing injury.

z

 

Be careful because this air mattress is thicker than
other mattresses and the height of the bed-side 
rails becomes relatively low, so it is easier for the 
user to roll over them. 

J

 

Do not transport the air mattress while the user 
is on the air mattress. 

z

 

Transport the air mattress while a person or heavy
object is not on the air mattress. If the air mattress
is transported while a person or heavy object is on
the air mattress, the person may fall off the air
mattress or the air mattress may be damaged.

J

 

Take care to prevent the air mattress from 
protruding from the bed and slipping off it. 

z

 

If the air mattress protrudes from the bed when
raising the back of the bed or when the user gets in
or out of the bed, the air mattress may slip off the
bed and the user also may fall off or topple over.
The air mattress is light in weight because of its
characteristics, so extra care is required.

J

 

Do not apply shock to the air mattress by 
standing up or jumping on the air mattress. 

z

 

There is a risk of injury due to falling or damage to
the air mattress.

J

 

Use the air mattress according to the user’s 
medical condition. 

z

 

Depending on the user's medical condition, the
user's medical condition could worsen by operating
the air mattress.

Содержание cococia Fuka

Страница 1: ...information about any serious incident related to this air mattress that occurs within the EU to the manufacturer and the regulating authority of the member country of residence Serious incident mean...

Страница 2: ...PRODUCTS 30 PRODUCT SYMBOL DEFINITIONS 31 AFTER SALES SERVICE 32 INTENDED USE J cococia F ka is an air mattress with an external pump which is designed to disperse body pressure when used for care in...

Страница 3: ...at the product logo faces up and the blowing tube is at the foot end of the user Head end Foot end CPR valve CPR label Top Plug Product logo Warning label Snap button Product identification label Blow...

Страница 4: ...on label Operation Panel Enlarged View Power button Status display Back raised mode button Max inflate mode button Hardness adjustment button Alternate pressure button Handle Blowing tube insertion po...

Страница 5: ...ction manual store it in a place that can be easily accessed for later reference About the warning CPR and product ID labels zWarning and precautions requiring special attention are described on label...

Страница 6: ...sk of unexpected gaps being created and part of the body getting caught resulting in injury J When getting in and out of the bed air mattress or taking a sitting position be careful not to fall or top...

Страница 7: ...Take care when handling the pump zThe air mattress may malfunction causing injury failure or damage In addition there is a risk of electric shock or fire due to a short circuit x Do not step on press...

Страница 8: ...stallation or improper connection or fixing may cause malfunction or result in an inability to supply air so the body pressure may not be dispersed effectively possibly causing bedsores zImproper fixi...

Страница 9: ...cted service life of t o ears o maintain the condition of the pump have the pump serviced regularl according to the schedule recommended o not use unapproved accessories or attempt to modif disassembl...

Страница 10: ...replace it with a new one For the replacement procedure contact your distributor see Contact Information on p 32 zIf the inside of the air mattress is stained or damaged contact your distributor see C...

Страница 11: ...OFF When ON is set the mode is set to OFF automatically after 60 minutes elapse WARNING zAdjust the usage time according to the user s medical condition If the internal pressure of the air cells cont...

Страница 12: ...p and the blowing tube is at the foot end of the user zCheck that the CPR valve plug points to CLOSE If it points to OPEN turn the plug to the CLOSE position WARNING zPlace the air mattress directly o...

Страница 13: ...sides of the coupling inward from both sides and insert into the blowing tube insertion port of the pump zInsert until you hear a click Check that both hooks on the left and right and the insertion li...

Страница 14: ...the pump Do not spill water on the pump or touch it with wet hands zWhen installing the pump do not bend the blowing tube Sufficient air may not be supplied possibly causing bedsores zTake care when...

Страница 15: ...ible causing electric shock or fire 5 Connecting to the power supply WARNING z Do not plug the power cord into a multiple socket outlet Plugging the power cord into a multiple socket outlet or power s...

Страница 16: ...ble of the pump to the outlet and hold down the power button for two seconds The pump starts working and the air cells expand Adjust the hardness of the air mattress according to the weight of the use...

Страница 17: ...ing of each function J Hold the CPR valve at the head end of the air mattress see the figure in 2 How to lay the sheet and turn the plug from CLOSE to the OPEN position zWhen supplying air to the air...

Страница 18: ...nants blood feces etc remove them Use soapy water commercially available soap such as neutral detergent diluted with water to wipe the surface of the cover on the air mattress to remove stains CAUTION...

Страница 19: ...the cover and therefore do not need to be maintained frequently zWhen maintaining the air cells do not separate each air cell from the air mattress Remove the coupling from the pump and discharge air...

Страница 20: ...handling method of each disinfectant z76 9 81 4 z70 z0 05 0 2 z0 05 0 2 z0 05 Ethanol for disinfection Isopropanol benzalkonium chloride benzethonium chloride chlorhexidine gluconate Replacing the fil...

Страница 21: ...ection J For safe use inspect the parts at least once a year The parts will exhibit wear and deterioration depending on the frequency of use and the environment Regularly inspect the following items J...

Страница 22: ...e pump Is the CPR valve set to OPEN Turn the plug of the CPR valve to the CLOSE position Air is not present in some air cells Is the alternate pressure lamp ON Since the alternate pressure is set to O...

Страница 23: ...the pump Is the pump hooked onto a part that rattles Hook the pump onto a part that does not rattle or place it Contacting the bottom Is the back section base of the bed raised while the back raised...

Страница 24: ...ward from both sides and remove the coupling from the pump CAUTION zWhen removing the coupling from the pump press the levers on both sides of the coupling and pull the coupling out of the pump Do not...

Страница 25: ...educe the odor zKeep the instruction manual in a safe place so that it does not become lost CAUTION zStore the product within the specified storage temperature humidity and air pressure ranges Failure...

Страница 26: ...Size cm Width 25 Depth 11 Height 22 Material Case ABS resin flame resistant chemical resistant Power supply Plug 2P Length 4 6 m Product weight kg 2 2 Guaranteed conditions Operating temperature humid...

Страница 27: ...her than those specified and sold by the manufacturers of Cococia Fuka are used as replacement parts for internal components it may result in an increase in emission or a decline in immunity of Cococi...

Страница 28: ...trengths from fixed RF transmitters as determined by an electromagnetic site survey must be less than the compliance level in each frequency range Do not use the pump for Cococia F ka and portable and...

Страница 29: ...itter in watts W according to the transmitter manufacturer NOTE1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE2 These guidelines may not apply in all situat...

Страница 30: ...ommunication devices are used The electromagnetic interference between the RF communication device and the pump for Cococia F ka can be prevented by maintaining the minimum distance between the two as...

Страница 31: ...ombination check the instruction manuals for beds bed side rails and swing arm bed grips side grips and Paramount Bed s catalogs and select suitable products that meet the following suitability standa...

Страница 32: ...lease request for repair work Turns o automatically in 120 minutes Lit up ON Max in ate mode selection Turns o automatically in 60 minutes Lit up ON Be careful not to get a body part caught in the gap...

Страница 33: ...unt Bed keeps replacement parts necessary to maintain stretcher performance in stock for at least 6 years after the discontinuation of production 3 Questions regarding after sales service Contact us s...

Страница 34: ...MEMO 33...

Страница 35: ...MEMO 34...

Страница 36: ...Original Instruction Manual Made by TorindoCo Ltd 2020 11 AL300429 V1 01...

Отзывы: