Cables, Connectors, and Pin Assignments
E-26
9161-A2-GH30-30
April 1998
T1 Mass Termination Cable
A T1 mass termination cable is available to connect up to seven NAMs mounted
in a 9000 Series Access Carrier to an M66 block. The T1 mass termination cable
is a 5-foot RJ48H cable consisting of a 50-pin plug at one end and seven RJ48C
plugs at the other end. The following shows pin assignments for the RJ48H
connector.
RJ48H Connector Pinouts for T1 Mass Termination Cable
Circuits
Line #
T1
1
R1
2
T
3
R
4
1
2
3
4
5
6
7
26
27
28
29
30
31
32
1
2
3
4
5
6
7
39
40
41
42
43
44
45
14
15
16
17
18
19
20
1
Receive Tip from Network
2
Receive Ring from Network
3
Transmit Tip to Network
4
Transmit Ring to Network
Содержание T1 Access Mux 916x
Страница 1: ...MODEL 916x 926x T1 ACCESS MUX TECHNICAL REFERENCE Document No 9161 A2 GH30 31 July 1998...
Страница 14: ...Contents viii 9161 A2 GH30 30 April 1998 F Technical Specifications G Equipment List Glossary...
Страница 34: ...Management and Control 2 6 9161 A2 GH30 30 April 1998 This page intentionally left blank...
Страница 54: ...User Interface 4 10 9161 A2 GH30 30 April 1998 This page intentionally left blank...
Страница 92: ...Setting Up 5 38 9161 A2 GH30 30 April 1998 Example Channel Allocation...
Страница 142: ...Security 6 10 9161 A2 GH30 30 April 1998 This page intentionally left blank...
Страница 168: ...Displaying System Information 7 26 9161 A2 GH30 30 April 1998 This page intentionally left blank...
Страница 244: ...Menus and Configuration Worksheets A 18 9161 A2 GH30 30 April 1998 This page intentionally left blank...
Страница 252: ...IP Addressing B 8 9161 A2 GH30 30 April 1998 This page intentionally left blank...
Страница 308: ...Technical Specifications F 8 9161 A2 GH30 30 April 1998 This page intentionally left blank...