3. Status and Statistics
9000-A2-GB33-20
May 2003
3-31
System and Test Status Messages
System and test status information is selected from the Status menu.
Main Menu
→
Status
→
System and Test Status
The following information is included on this screen:
Self-Test Results Messages (
Table 3-5
)
Last System Reset Date and Time
Health and Status Messages (
Table 3-6
)
Test Status Messages (
Table 3-7
)
Self-Test Results Messages
One of these self-test result messages appears in the Self-Test Results field at the
top of the System and Test Status screen.
Last System Reset Date and Time
This field indicates the last time the iMarc unit was reset. It appears after the
Self-Test Results field at the top of the System and Test Status screen.
Date is in mm/dd/yyyy format (month/day/year).
Time is in mm:ss format (minutes:seconds).
Table 3-5.
Self-Test Results Messages
Message
What It Indicates
What To Do
Failure
xxxxxxxx
An internal failure occurred
(xxxxxxxx
represents an
8-digit hexadecimal failure
code used by service
personnel).
Record the failure code
before resetting the unit;
otherwise, the error
information will be lost.
1. Record the failure code.
2. Reset the unit.
3. Contact your service
representative.
Passed
No problems were found
during power-on or reset.
No action needed.
Содержание FrameSaver SLV 9126
Страница 1: ...iMarc SLV Operations Guide Document No 9000 A2 GB33 20 May 2003 ...
Страница 36: ...2 Security and Logins 2 16 May 2003 9000 A2 GB33 20 ...
Страница 128: ...3 Status and Statistics 3 92 May 2003 9000 A2 GB33 20 ...
Страница 200: ...5 Troubleshooting 5 56 May 2003 9000 A2 GB33 20 ...
Страница 210: ...Index IN 10 May 2003 9000 A2 GB33 20 ...