4. Operation and Maintenance
9000-A2-GB33-20
May 2003
4-15
WARNING:
!
Each fan starts spinning as soon as the fan power cable is reconnected.
Keep your hair and clothes away from the fan blades.
6. Reconnect the LED ribbon cable, then reconnect the fan power cable. Verify
that all four fans are running.
7. Replace the front panel and tighten the captive screws.
CAUTION:
Do not leave the front panel assembly off the DSU for extended periods,
or the DSU will overheat.
Replacing the Front Panel Assembly
The System FAN LED on the front panel turns on when one or more of the front
panel fans has failed. Replace the front panel assembly as soon as possible after
this occurs. Refer all service to qualified personnel.
The procedure may be performed while the unit is running.
Procedure
To replace the front panel:
1. Loosen the captive screws holding on the front panel.
WARNING:
!
The fans continue to run until the fan power cable is removed. Keep your
hair and clothes away from the fan blades.
2. Carefully pull the front panel toward you. Verify that at least one of the fans
has failed.
3. Remove the fan power cable and LED ribbon cable, and set the old front panel
assembly aside.
WARNING:
!
Each fan starts spinning as soon as the fan power cable is reconnected.
Keep your hair and clothes away from the fan blades.
4. Take the new front panel and connect the LED cable, then connect the fan
power cable. Verify that all four fans are running.
5. Replace the front panel and tighten the captive screws. Verify that the FAN
LED is turned off.
Содержание FrameSaver SLV 9126
Страница 1: ...iMarc SLV Operations Guide Document No 9000 A2 GB33 20 May 2003 ...
Страница 36: ...2 Security and Logins 2 16 May 2003 9000 A2 GB33 20 ...
Страница 128: ...3 Status and Statistics 3 92 May 2003 9000 A2 GB33 20 ...
Страница 200: ...5 Troubleshooting 5 56 May 2003 9000 A2 GB33 20 ...
Страница 210: ...Index IN 10 May 2003 9000 A2 GB33 20 ...