3. Status and Statistics
9000-A2-GB33-20
May 2003
3-47
Status
Identifies whether the physical
interfaces, LMIs, and DLCIs are all
enabled and active for this PVC
connection.
Active *
The PVC is currently active.
Inactive
The PVC is inactive because:
– Alarm conditions and network
and SLV communication
status indicate that data
cannot be successfully
passed.
– The unit has disabled the
interface or frame relay link
due to internal operating
conventions.
– Activation of an alternate
virtual circuit is not warranted;
that is, no alarm condition on
the primary destination link
has been detected.
Disabled
The PVC cannot be activated and
is essentially disabled as a result
of how the unit was configured.
Possible causes:
– The physical interface at one
or both ends of the PVC is/are
disabled.
– The frame relay link on one or
both ends of the PVC is/are
disabled.
Invalid
Some portion of the PVC
connection is not fully configured.
* For the circuit to be active, both Source and Destination Statuses must be Active.
Table 3-10. PVC Connection Status (2 of 2)
Field
Value
What It Indicates