Typical Applications
3-4
9124-A2-GH30-00
June 1999 - Preliminary
If LAN probing, application layer probing, or packet capture capability is desired,
a NetScout probe can be used in conjunction with a FrameSaver 9124 at the
central site.
In the example below, the FrameSaver 9124 is connected to NetScout’s probe,
which is using NetScout’s NMS application to provide full probe capability at the
central or regional site.
Frame
Relay
Router
FrameSaver
9124
Unit
98-15873
NetScout
Probe
Frame
Relay
Network
Frame
Relay
Router
Remote
Sites
FrameSaver
9124
Unit
Frame
Relay
Router
FrameSaver
9624
Unit
Frame
Relay
Router
FrameSaver
9624
Unit
NetScout
NMS
Application
Central
Site
Diagnostic and statistical information is continuously collected every 15 minutes
for 24 hours by the FrameSaver SLV units, with daily totals for up to 5 days. This
information continues to be collected, even when frequent communication with
the management station is not possible or desired due to bandwidth restrictions
or network outages. As a result, the NMS application does not have to use
networking bandwidth and CPU time to repeatedly query the remote FrameSaver
unit for information, reducing network load and maximizing use of the information
collected.
FrameSaver units can also respond to multiple managers, and each manager
can pick and choose from the information collected, selecting and collecting only
the information that is important to them through internal thresholds in the
NetScout NMS.
Содержание FrameSaver SLV 9124
Страница 1: ...FrameSaverr SLV 9124 TECHNICAL REFERENCE Document No 9124 A2 GH30 00 June 1999 PRELIMINARY DRAFT ...
Страница 22: ...About the FrameSaver SLV 1 8 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 200: ...Configuration 8 78 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 286: ...Menu Hierarchy A 4 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 330: ...Cables Connectors and Pin Assignments D 10 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 346: ...Index IN 12 9124 A2 GH30 00 June 1999 This page intentionally left blank ...