Troubleshooting
11-18
9124-A2-GH30-00
June 1999 - Preliminary
Aborting All Tests
Use the Abort All Tests selection from the Test menu to abort all tests running on
all interfaces, with exception to DTE-initiated loopbacks. To abort individual tests
that are active, see
Starting and Stopping a Test
on page 11-17.
"
Procedure
To abort all tests on all interfaces:
1. Follow this menu selection sequence:
Main Menu
→
Test
2. Select Abort All Tests and press Enter.
Command Complete
appears when all tests on all interfaces have been
stopped.
NOTE:
Abort All Tests does not interrupt DTE-initiated loopbacks.
Determining Test Status and Results
Current test status and results are available on the:
H
Test screen from which you execute the test (Results column)
H
System and Test Status screen
H
NMS
H
Test LED
PVC Tests
PVC tests can be run on a requested DLCI for a selected interface.
H
When PVC tests are on a multiplexed DLCI between FrameSaver units, they
are nondisruptive to data, so user data can continue to be sent during a test.
H
If the device at one end of the circuit is not a FrameSaver unit, PVC tests are
on a standard DLCI and are disruptive to data.
Loopback, and send/monitor pattern tests are available for each interface on the
selected DLCI. Units should be at each end of the circuit. If a PVC Loopback is
started at one end of the circuit, the other end can send and monitor pattern
tests.
NOTE:
Errors encountered during these tests may be caused by mismatched CIRs
in the two FrameSaver units. If errors are detected, verify the CIR
configuration and retest.
Содержание FrameSaver SLV 9124
Страница 1: ...FrameSaverr SLV 9124 TECHNICAL REFERENCE Document No 9124 A2 GH30 00 June 1999 PRELIMINARY DRAFT ...
Страница 22: ...About the FrameSaver SLV 1 8 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 200: ...Configuration 8 78 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 286: ...Menu Hierarchy A 4 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 330: ...Cables Connectors and Pin Assignments D 10 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 346: ...Index IN 12 9124 A2 GH30 00 June 1999 This page intentionally left blank ...