Configuration
8-18
9124-A2-GH30-00
June 1999 - Preliminary
Setting Up Management
For remote sites, only SNMP management needs to be set up. For the central
site, local management between the unit and the router must be set up along with
SNMP management.
"
Procedure
To set up SNMP management:
1. Select General SNMP Management.
Configuration
→
Management and Communication
→
General SNMP Management
2. Minimally, set Name 1 Access to Read/Write.
3. Save your entries.
"
Procedure
To set up local management at the central site unit:
1. Create a DLCI for the data port.
Main Menu
→
Configuration
→
Data Ports
→
DLCI Records
2. Select Management PVC.
Configuration
→
Management and Communication
→
Management PVC
3. Make the DLCI Record a management DLCI to create a Management PVC.
Minimally, enter the following options for each of the DLCI Records created:
— Name for the management DLCI
— Special and the IP Address for the interface if it is different from the Node
IP Address
— Primary Link for this DLCI (i.e., the DLCI’s primary destination interface)
— Primary DLCI (i.e., the DLCI number at the other end of the PVC)
4. Save your changes.
Содержание FrameSaver SLV 9124
Страница 1: ...FrameSaverr SLV 9124 TECHNICAL REFERENCE Document No 9124 A2 GH30 00 June 1999 PRELIMINARY DRAFT ...
Страница 22: ...About the FrameSaver SLV 1 8 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 200: ...Configuration 8 78 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 286: ...Menu Hierarchy A 4 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 330: ...Cables Connectors and Pin Assignments D 10 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 346: ...Index IN 12 9124 A2 GH30 00 June 1999 This page intentionally left blank ...