background image

17

Government Requirements

Certain governments require that instructions pertaining to connection to the telephone 
network be included in the user documentation. Specific instructions are listed in the 
following sections.

United States
Notice to Users of the Telephone Network

This equipment complies with Part 68 of the FCC rules. On the back of the access 
carrier is a label that contains, among other information, the FCC registration number for 
this equipment. If the unit comes with an integral modem, the Ringer Equivalence 
Number (REN) will also be labeled. If requested, please provide this information to your 
telephone company.

The REN is used to determine the number of devices that may be connected to the 
telephone line. Excessive RENs on the line may result in the devices not ringing in 
response to an incoming call. In most, but not all areas, the sum of RENs should not 
exceed five (5.0). To be certain of the number of devices that can be connected to the 
line, as determined by the total RENs, contact the local telephone company.

If your unit causes harm to the telephone network, the telephone company may 
discontinue your service temporarily. If possible, they will notify you in advance. But if 
advance notice is not practical, you will be notified as soon as possible. You will be 
advised of your right to file a complaint with the FCC.

Your telephone company may make changes in facilities, equipment, operations, or 
procedures that could affect the proper operation of your equipment. If so, you will be 
given advance notice so as to give you an opportunity to maintain uninterrupted service.

No repairs may be performed by the user. Should you experience difficulty with this 
equipment, refer to

 

Warranty, Sales, Service, and Training Information

 on page 20.

For Digital Data Service (DDS) installations, inform the local telephone company of the 
appropriate facility interface code for the service you desire.

DDS Facility Interface Codes

The DDS Service Order Number is 6.0Y. The USOC jack required is RJ48S.

Make the T1 network connection using a Universal Service Order Code (USOC) type 
RJ48C jack for single-line installations and type RJ48H jack for multiline installations. 
Specify both the Service Order Code 6.0F, as well as the proper Facility Interface Code, 
to the telephone company when ordering the T1 line. The T1 equipment can be 
configured to support any of the framing format and line signaling techniques shown in 
the table below. The T1 equipment's configuration must correspond to the T1 line's 
parameters. 

Interface Code

Data Rate (bps)

04DU5-56

56,000

04DU5-64

64,000

Содержание 9161 Single T1

Страница 1: ...the following Power supply already installed and power cord Power supply fan tray already installed Fan tray for NAMs already installed Baffle for heat deflection including extender brackets for insta...

Страница 2: ...de the 9261 NAM I O to the Dual T1 NAM I O for use in the access carrier Contact your sales representative to order an option Before You Install the Access Carrier Make sure you have A dedicated groun...

Страница 3: ...ration When performing installation procedures however take proper static control precautions to prevent damage to equipment If you are not sure of the proper static control precautions contact your n...

Страница 4: ...Bottom up installation keeps the cabinet from becoming top heavy Install the access carrier into the cabinet rack before installing any cards in the unit Use some type of strain relief to support mult...

Страница 5: ...ccess carrier against the front rail of the cabinet allowing the installed machine screws on each side to pass through the keyholes 3 Lower the access carrier into place allowing the keyholes to slide...

Страница 6: ...ght side of the carrier Align the hole of the nut with the hole in the rail 2 Place the access carrier against the front rail of the cabinet allowing the installed machine screws to pass through the k...

Страница 7: ...er to the instructions that came with the power supply AC Power Supply for 5 Slot Housing and 9000 Series Access Carrier Installation Instructions Document No 9000 A2 GN17 for installation information...

Страница 8: ...in circulating air and the green LED lights If not check potential reasons in Troubleshooting in the appropriate product manual Installing the Baffle A baffle with self retaining nuts is provided for...

Страница 9: ...3 Using four of the screws provided attach the baffle to the rack immediately below the carrier as shown Baffle 19 Cabinet 23 Cabinet 01 15789 01 Self Retaining Nuts Extender Bracket Self Retaining Nu...

Страница 10: ...ed NAMS are installed from the rear NOTE Cards can be added or removed without powering down the unit I O Card Installation The I O card inserts into the rear of the access carrier and directly connec...

Страница 11: ...1 Select the proper filler panel size to cover empty slots 2 At the rear of the carrier align the filler panel with the upper and lower tracks of the slot then screw the panel into place using the scr...

Страница 12: ...unused NAM slots and captive screws to install them Filler panels provided will cover either four two or one empty NAM slot s Procedure 1 Select the proper filler panel size to cover the empty slots...

Страница 13: ...h the installation Procedure 1 Insert the power cord into the I O card s power connector 2 Plug the other end into a power outlet Verification Checklist Did the green power supply LED light Did the gr...

Страница 14: ...ysical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 35 F to 122 F 1 7 C to 50 C 4 F to 158 F 20 C to 70 C 5 to 85 noncondensing Withstands normal shippin...

Страница 15: ...ersons will walk on the power cord 6 Disconnect power before servicing 7 General purpose cables are provided with this product A UL Listed CSA Certified minimum No 26 AWG telecommunications cable is p...

Страница 16: ...imeter in length regardless of the width UNITED STATES EMI NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules T...

Страница 17: ...ance But if advance notice is not practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make changes in facil...

Страница 18: ...le Identification SPID number and one local phone number Capability Package R for 2B service which supports up to two circuit switched B channels BRI B1 and BRI B2 with two SPID numbers and two local...

Страница 19: ...the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or altera...

Страница 20: ...ormation by fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about th...

Отзывы: