C. Configuration Options
3150-A2-GB24-10
March 2001
C-11
ComDisconnect:
Next Edit Clear Prev
Carrier Communication Port Disconnect String. Specifies the communication port’s
disconnect string. The communication port’s disconnect string is sent to the external
device if either you or the CSU wants to command the external device to disconnect. The
external device must be in command mode before this command can be sent, so the
escape sequence will always be sent before the disconnect string. The disconnect string
is an ASCII text string and may be up to 20 characters in length. If the disconnect string is
NULL, then no disconnect string is sent out.
Edit
–
Allows you to edit and/or display the disconnect string using the generic text string
entry screen.
Clear
–
Allows you to clear the disconnect string. The disconnect string is set to a null
string.
NOTES:
– This configuration option is available on carrier-mounted CSUs only.
▲
– This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
Com Type: Async
Next Async Sync Prev
Communication Port Type. Specifies whether the communication port uses synchronous
or asynchronous operation when it is configured as the SNMP management link.
Async
–
Configures the communication port for asynchronous operation.
Sync
–
Configures the communication port for synchronous operation.
NOTE: This configuration option is not available if the Com Use configuration option is
set to ASCII or Term. In these cases, the communication port is always asynchronous.
Com Clk: Int
Next Int Ext Prev
Communication Port Synchronous Clock. Specifies whether the communication port uses
internal or external clocking when it is configured for synchronous operation.
Int
–
Configures the communication port for internal clocking.
Ext
–
Configures the communication port for external clocking.
NOTE: This configuration option is not available if the Com Type configuration option is
set to Async.
Table C-4.
User Interface Configuration Options (5 of 10)
Содержание 3151
Страница 1: ...ACCULINK CSU Models 3150 A4 and 3151 Operator s Guide Document No 3150 A2 GB24 10 March 2001 ...
Страница 16: ...About This Guide x March 2001 3150 A2 GB24 10 ...
Страница 28: ...2 Installation 2 8 March 2001 3150 A2 GB24 10 ...
Страница 40: ...3 Using the Front Panel 3 12 March 2001 3150 A2 GB24 10 ...
Страница 66: ...4 Configuration 4 26 March 2001 3150 A2 GB24 10 ...
Страница 74: ...5 Security 5 8 March 2001 3150 A2 GB24 10 ...
Страница 118: ...8 Testing 8 18 March 2001 3150 A2 GB24 10 ...
Страница 120: ...A Front Panel Menu A 2 March 2001 3150 A2 GB24 10 ...
Страница 152: ...C Configuration Options C 30 March 2001 3150 A2 GB24 10 ...
Страница 168: ...E Pin Assignments E 10 March 2001 3150 A2 GB24 10 ...
Страница 192: ...F SNMP MIB Objects F 24 March 2001 3150 A2 GB24 10 ...
Страница 218: ...J Equipment List J 2 March 2001 3150 A2 GB24 10 ...