C. Configuration Options
3150-A2-GB24-10
March 2001
C-9
ComConnPrefix:
Next Edit Clear Prev
Carrier Communication Port Connect Prefix. Specifies the connect prefix to the dial
directory phone number. When you make a connection or the CSU automatically makes a
connection (dial-out alarms or traps) through the communication port, the connect prefix
and the dial directory phone number are used to establish the connection. The connect
prefix is an ASCII text string and may be up to 20 characters in length. If the connect
prefix is NULL, then no connect prefix is used.
Edit
–
Allows you to edit and/or display the connect prefix using the generic text string
entry screen.
Clear
–
Allows you to clear the connect prefix. The connect prefix is set to a null string.
NOTES:
– This configuration option is available on carrier-mounted CSUs only.
▲
– This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
CAUTION: If ComExtDev is configured for Other and the external device requires
characters after the dial phone number, you must append the characters to the phone
number.
ComConnected:
Next Edit Clear Prev
Carrier Communication Port Connect Indication String. Specifies the communication
port’s connect indication string. When you make a connection or the CSU automatically
makes a connection (dial-out alarms or traps) through the communication port, this string
determines that the connection has been established. The connect indication string is an
ASCII text string and may be up to 20 characters in length. If the connect indication string
is not received within 1 minute, it will time-out the connection. If the connect indication
string is NULL, the communication port’s receive data stream is not searched and a
transition in the Carrier Detect (CD) lead is used to determine that a connection has been
established.
Edit
–
Allows you to edit and/or display the case-sensitive connect indication string using
the generic text string entry screen.
Clear
–
Allows you to clear the connect indication string. The connect indication string is
set to a null string.
NOTES:
– This configuration option is available on carrier-mounted CSUs only.
▲
– This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
Table C-4.
User Interface Configuration Options (3 of 10)
Содержание 3151
Страница 1: ...ACCULINK CSU Models 3150 A4 and 3151 Operator s Guide Document No 3150 A2 GB24 10 March 2001 ...
Страница 16: ...About This Guide x March 2001 3150 A2 GB24 10 ...
Страница 28: ...2 Installation 2 8 March 2001 3150 A2 GB24 10 ...
Страница 40: ...3 Using the Front Panel 3 12 March 2001 3150 A2 GB24 10 ...
Страница 66: ...4 Configuration 4 26 March 2001 3150 A2 GB24 10 ...
Страница 74: ...5 Security 5 8 March 2001 3150 A2 GB24 10 ...
Страница 118: ...8 Testing 8 18 March 2001 3150 A2 GB24 10 ...
Страница 120: ...A Front Panel Menu A 2 March 2001 3150 A2 GB24 10 ...
Страница 152: ...C Configuration Options C 30 March 2001 3150 A2 GB24 10 ...
Страница 168: ...E Pin Assignments E 10 March 2001 3150 A2 GB24 10 ...
Страница 192: ...F SNMP MIB Objects F 24 March 2001 3150 A2 GB24 10 ...
Страница 218: ...J Equipment List J 2 March 2001 3150 A2 GB24 10 ...
Страница 228: ...Glossary GL 10 March 2001 3150 A2 GB24 10 ...