PAGE 16
EVO/DGP System Programming
(see “Optional External Temperature Sensor” on page 9). If set as a
temperature input, Grafica represents it as the outside temperature
on the System Status screen next to the word “OUT”.
Option
[7]
OFF = Temperature sensor input (default)
Option
[7]
ON = Zone input
Keypad Tamper
S
ECTION
[002]: O
PTION
[8]
When the keypad tamper option is enabled and the keypad's anti-
tamper switch (optional) is triggered, the keypad will send a Tamper
report to the control panel via the combus.
Option
[8]
OFF = Grafica’s tamper option is disabled (default)
Option
[8]
ON = Grafica’s tamper option is enabled
Beep on Trouble
S
ECTION
[003]: O
PTIONS
[1]
TO
[4]
Potential troubles have been sorted into groups. With these options
enabled, the keypad will emit an intermittent beep tone whenever a
trouble condition occurs from one of the trouble groups. The
intermittent beep will remain activated until the user enters Grafica’s
Trouble Display or if the trouble is resolved. For a list of troubles, see
the appropriate control panel’s
Reference and Installation Manual
.
The intermittent beep will be re-initialized whenever the trouble
condition reoccurs.
System and Clock Trouble Beep
S
ECTION
[003]: O
PTION
[1]
Option
[1]
OFF = Beep disabled (default)
Option
[1]
ON
= Beep on: System Troubles and Clock Loss
Communicator Trouble Beep
S
ECTION
[003]: O
PTION
[2]
Option
[2]
OFF = Beep disabled
Option
[2]
ON = Beep on: Communicator Troubles (default)
Module and Combus Trouble Beep
S
ECTION
[003]: O
PTION
[3]
Option
[3]
OFF = Beep disabled (default)
Option
[3]
ON = Beep on: Module and Combus Troubles