background image

EVO/DGP System Programming

PAGE 15

Confidential Mode

S

ECTION

 [002]: O

PTIONS

 [4] 

AND

 [5]

WARNING:

 For UL installations, Confidential Mode must be disabled 

(option [4] = OFF)
If Confidential Mode is enabled and actions are not performed on the 
Grafica keypad for a period of time, the screen will display the time, 
date and all LEDs on the keypad will turn off until either a key is 
pressed, or an code # is entered. The period of time in which no 
action is performed is defined by the Confidential Mode Timer (see 
“Confidential Mode Timer” on page 17).
Grafica will switch from Confidential Mode to Normal Mode when a 
key is pressed or a code # (PIN) is entered. In normal mode, Grafica 
displays the date, time and the status of the zones for every partition 
assigned to the keypad. In addition, the alarm memory, bypassed 
zones and troubles will also be displayed.

S

ECTION

 [002]: O

PTION

 [4]

Option

 [4]

 OFF  = Normal Mode (default)

Option

 [4] 

ON  = Confidential Mode

S

ECTION

 [002]: O

PTION

 [5]

Option 

[5]

 OFF  = Exit confidential mode by entering an code # (PIN) 

(default)
Option 

[5]

 ON  = Exit confidential mode by pressing any key

NOTE:

 Section 

[002]

 option 

[5]

 will work only if option 

[4]

 in section

 

[002]

 is enabled.

Exit Delay Beep

S

ECTION

 [002]: O

PTION

 [6]

The keypad can beep once every second or play a selected tone 
during the Exit Delay Timer. During the final 10 seconds only the 
beep tone will be heard (at a faster interval) to provide a final warning 
before the area is armed. 
Option 

[6] 

OFF  = Exit Delay beep is disabled

Option 

[6]

 ON  = Exit Delay beep is enabled (default)

Keypad Input Type

S

ECTION

 [002]: O

PTION

 [7]

Grafica’s keypad input (see “Keypad Input” on page 9) can be utilized 
as a zone or as an input for an optional external temperature sensor 

Содержание K07C

Страница 1: ...K07C Grafica Color Keypad V1 0 Reference and Installation Manual ...

Страница 2: ...d or its affiliates in Canada the United States and or other countries For the latest product approvals such as UL and CE please visit www paradox com 2009 Paradox Security Systems Ltd All rights reserved Specifications may change without prior notice Patents One or more of the following US patents may apply 7046142 6215399 6111256 6104319 5920259 5886632 5721542 5287111 5119069 5077549 and RE3940...

Страница 3: ...pad Input 9 Temperature Sensors 9 Mounting Grafica 10 Removing Grafica 11 Firmware Upgrade 12 Imperial System Programming 12 EVO DGP System Programming 12 Entering Module Programming Mode 13 Programming Methods 13 Feature Select Programming 13 Decimal Programming 13 Hexadecimal Programming 13 Keypad Options 14 Temperature Broadcast 18 EVO DGP Programming Sections 20 ...

Страница 4: ...ation Fault indication message will appear on the LCD screen Anti tamper switch Yes optional Display TFT screen Thin Film Transistor Under electrostatic discharge ESD conditions the screen may go blank To reset the screen press any key or wait one minute Screen size 9cm 3 5 Screen resolution 320x240 Colors 64k colors Compatibility Imperial V32 EVO48 192 DGP NE96 DGP 848 NOTE Imperial systems requi...

Страница 5: ...h its full color LCD screen Grafica offers the unique ability to view zone locations on floor plan drawings Other features include a photo screensaver downloadable tunes and bitmaps for many functions a smart search engine for users and zones and an alarm clock Features Photo screensaver Downloadable tunes and bitmaps Smart search engine for users and zones Alarm clock Indoor temperature sensor Ou...

Страница 6: ...and in a direction that provides the best viewing angle Figure 1 Keypad Cover Clearance Grafica s keypad cover requires sufficient space in order to open properly Ensure a clearance of approximately 9cm 3 5in between the bottom of the keypad and possible obstructions such as a light switch that may prevent the keypad from opening properly see Figure 2 Figure 2 10 0 20 A 9cm 3 5 B Obstruction A B ...

Страница 7: ...and or daisy chain configuration The Multibus Combus consists of four wires that provide power and two way communication between the control panel and all modules connected to it Connect the four terminals labelled RED BLK GRN and YEL of the module to the corresponding terminals on the control panel see Figure 4 on page 8 For the maximum allowable installation distance refer to the Imperial System...

Страница 8: ...is set at 600mS and cannot be programmed Grafica B C Multibus Combus 1 K9 EOL Connecting Grafica with Keypad Input A To other modules B To control panel C Door Contact A To other modules B To control panel C Temperature Sensor TEMP07 Grafica A B C Multibus Combus Connecting Grafica with Temp Sensor 30 5m 100ft max ...

Страница 9: ...re Sensor If the Inside Temp ON option is enabled the built in temperature sensor s see Figure 6 reading will display on the System Status screen next to the word IN If another temperature sensor is required see Optional External Temperature Sensor Figure 6 Optional External Temperature Sensor Grafica offers an optional external temperature sensor TEMP07 that connects to Grafica s keypad input see...

Страница 10: ...e B see Figure 7 Figure 7 2 Slide Grafica s open slots labeled A see Figure 8 onto the metal wall plate s tabs labeled A see Figure 7 Figure 8 3 Gently apply downward pressure to snap Grafica onto the metal wall plate A Metal wall plate tabs B Metal wall plate C Optional screw A B C A A Clip Grafica back view ...

Страница 11: ...b see Figure 7 on page 10 Removing Grafica 1 If required remove the optional screw see Figure 7 on page 10 2 Gently slide the unit upwards with your hands until it separates from the metal wall plate see Figure 9 Figure 9 Figure 10 A A Metal wall plate Grafica partial view Used with EVO DGP panels only 307USB and Memory Key connections ...

Страница 12: ...structions go to paradox com Software WinLoad and locate the Firmware Upgrade Instructions document NOTE You must first disconnect the keypad s GRN and YEL combus wires before following instructions Chapter 3 Imperial System Programming For Imperial systems all Grafica programming and options are set using BabyWare software For more information refer to the BabyWare instructions in the Imperial Sy...

Страница 13: ...version and serial number Programming Methods The following methods can be used when programming the Grafica keypad Feature Select Programming You can program sections by enabling or disabling options Within these sections keys 1 to 8 or scroll keys represent a specific Grafica option Use the scroll keys to highlight the desired option and press the corresponding action key to enable or disable th...

Страница 14: ...igits are replaced by asterisks default Option 1 ON Code PIN digits will be displayed Display Exit Delay SECTION 002 OPTION 2 Based on the user s needs an Exit Delay Timer can be programmed to provide the user time to exit the partition before the system is armed If this option is enabled the Exit Delay Timer s countdown will appear on the LCD screen next to the hourglass icon Option 2 OFF Exit de...

Страница 15: ...igned to the keypad In addition the alarm memory bypassed zones and troubles will also be displayed SECTION 002 OPTION 4 Option 4 OFF Normal Mode default Option 4 ON Confidential Mode SECTION 002 OPTION 5 Option 5 OFF Exit confidential mode by entering an code PIN default Option 5 ON Exit confidential mode by pressing any key NOTE Section 002 option 5 will work only if option 4 in section 002 is e...

Страница 16: ...e been sorted into groups With these options enabled the keypad will emit an intermittent beep tone whenever a trouble condition occurs from one of the trouble groups The intermittent beep will remain activated until the user enters Grafica s Trouble Display or if the trouble is resolved For a list of troubles see the appropriate control panel s Reference and Installation Manual The intermittent b...

Страница 17: ...erature Calibration SECTION 005 OUTSIDE TEMPERATURE CALIBRATION SECTION 006 INSIDE TEMPERATURE CALIBRATION The outside temperature reading is that given by the optional external temperature sensor see Optional External Temperature Sensor on page 9 when connected to Grafica s input The inside temperature reading is that given by Grafica s built in temperature sensor see Built in Temperature Sensor ...

Страница 18: ...nd 009 Outdoor Temperature From Another Grafica SECTION 007 OPTION 2 Option 2 OFF Disabled default Option 2 ON Enabled NOTE Use this section in conjunction with sections 010 and 011 Send Indoor Outdoor Temp to Other Grafica Keypads SECTION 007 OPTION 4 Option 4 OFF Disabled default Option 4 ON Enabled For Indoor Temp Import all Temp Data From SECTION 008 When section 007 option 1 is enabled enter ...

Страница 19: ...a keypad from which you would like to import temperature data Which Imported Temp Value is Displayed as Outdoor Temp SECTION 011 When a Grafica serial number is entered in section 010 the keypads indoor and outdoor temperatures are sent Select which incoming value will be displayed as the keypad s outdoor temperature Indoor temperature 001 Outdoor temperature 002 ...

Страница 20: ... N Disabled U Enabled 6 Partition 6 N Disabled U Enabled 7 Partition 7 N Disabled U Enabled 8 Partition 8 N Disabled U Enabled Section 002 General Options 1 Option OFF ON 1 Display code entry U Disabled N Enabled 2 Display exit delay N Disabled U Enabled 3 Display entry delay N Disabled U Enabled 4 Confidential mode U Disabled N Enabled 5 To exit confidential mode U Enter Code N Press key 6 Exit d...

Страница 21: ...N Enabled 4 All zone trouble beep U Disabled N Enabled 5 Future use N N 6 Future use N N 7 Time format 24h AM PM U 24h N AM PM 8 Date display U yy mm dd N dd mm yy Section 004 Confidential Mode Timer Data ___ ___ ___ 005 to 255 seconds Section 005 Outside Temperature Calibration Data ___ ___ ___ 001 to 254 000 and 128 no calibration value Section 006 Inside Temperature Calibration Data ___ ___ ___...

Страница 22: ...Indoor Temp Import all Temp Data From Data __ __ __ __ __ __ __ __ Another Grafica s serial Section 009 Which of the Imported Temp Values Will be Displayed as Indoor Temp Data ___ ___ ___ 001 Internal 002 External Section 010 For Outdoor Temp Import all Temp Data From Data __ __ __ __ __ __ __ __ Another Grafica s serial Section 011 Which of the Imported Temp Values Will be Displayed as Outdoor Te...

Страница 23: ... 16 C Clock trouble beep 16 Code entry 14 Combus trouble beep 16 Communicator trouble beep 16 Confidential mode 15 Confidential mode timer 17 Connections 7 Cover clearance 6 D Date format 17 Decimal programming 13 DGP 848 14 Display code entry 14 Display exit delay 14 E Entry delay 14 EOL definition 8 EVO DGP systems 12 Exit delay 14 Exit delay beep 15 ...

Страница 24: ...ature 18 Input 9 Input type 15 Installation height 6 K Keypad clearance 6 Keypad Input 9 Keypad input type 15 Keypad options 14 Keypad tamper 16 M Metal wall plate 7 Module programming mode 13 Module trouble beep 16 Mounting 7 10 O Outdoor temperature 18 Overview 5 P Partition 14 Partition assignment 14 Programming methods 13 Programming mode 13 Programming sections 20 ...

Страница 25: ...6 T Tamper 16 Temperature indoor outdoor 18 Temperature broadcast 18 Temperature calibration 17 Temperature sensor 9 Time format 17 Trouble beep 16 U UL installations 15 Upgrade firmware 12 Uploading downloading data 19 V Viewing angle 6 W Wall plate 7 Wiring 7 Z Zone trouble beep 17 ...

Страница 26: ......

Страница 27: ......

Страница 28: ...ort in Canada or the U S call 1 800 791 1919 Monday to Friday from 8 00 a m to 8 00 p m EST For technical support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 00 p m EST Please feel free to visit our website at www paradox com ...

Отзывы: