PAGE 18
EVO/DGP System Programming
Temperature Broadcast
Using sections [007] to [011], you can define which temperature readings
are used for which purpose. For example, a Grafica keypad is installed in
the main house as well as the guest house. The indoor temperature from
the guest house keypad can be displayed as the outdoor temperature of
the main house keypad, allowing you to monitor the indoor temperatures
of both buildings.
Indoor Temperature From Another Grafica
S
ECTION
[007]: O
PTION
[1]
Option
[1]
OFF = Disabled (default)
Option
[1]
ON = Enabled
NOTE:
Use this section in conjunction with sections
[008]
and
[009]
.
Outdoor Temperature From Another Grafica
S
ECTION
[007]: O
PTION
[2]
Option
[2]
OFF = Disabled (default)
Option
[2]
ON = Enabled
NOTE:
Use this section in conjunction with sections
[010]
and
[011]
.
Send Indoor/Outdoor Temp. to Other Grafica Keypads
S
ECTION
[007]: O
PTION
[4]
Option
[4]
OFF = Disabled (default)
Option
[4]
ON = Enabled
For Indoor Temp., Import all Temp. Data From:
S
ECTION
[008]
When section
[007]
option
[1]
is enabled, enter the serial number of
the Grafica keypad from which you would like to import temperature
data.
Which Imported Temp. Value is Displayed as Indoor
Temp.
S
ECTION
[009]
When a Grafica serial number is entered in section
[008]
, the
keypads indoor and outdoor temperatures are sent. Select which
incoming value will be displayed as the keypad’s indoor temperature.
Indoor temperature
=
(001)
Outdoor temperature =
(002)
Содержание K07C
Страница 1: ...K07C Grafica Color Keypad V1 0 Reference and Installation Manual ...
Страница 26: ......
Страница 27: ......