All Zone Trouble Beep
S
ECTION
[003]: O
PTION
[4]
Option
[4]
OFF = Beep disabled (default)
Option
[4]
ON = Beep on: All Zone Troubles
Time Format
S
ECTION
[003]: O
PTION
[7]
Option
[7]
OFF = 24 hour format (default)
Option
[7]
ON = 12 hour format: AM/PM
Date Format
S
ECTION
[003]: O
PTION
[8]
Option
[8]
OFF = Date format: yy-mm-dd (default)
Option
[8]
ON = Date format: dd-mm-yy
Confidential Mode Timer
S
ECTION
[004]
Section
[004]
determines the amount of time that must elapse
without performing an action on the keypad before the keypad enters
Confidential Mode (see “Confidential Mode” on page 15). The
Confidential Mode Timer can be any value from 005 to 255 seconds
(default: 120 seconds)
.
Temperature Calibration
S
ECTION
[005] = O
UTSIDE
T
EMPERATURE
C
ALIBRATION
S
ECTION
[006] = I
NSIDE
T
EMPERATURE
C
ALIBRATION
The outside temperature reading is that given by the optional
external temperature sensor (see “Optional External Temperature
Sensor” on page 9) when connected to Grafica’s input. The inside
temperature reading is that given by Grafica’s built-in temperature
sensor (see “Built-in Temperature Sensor” on page 9). If the
temperature reading is inaccurate, enter a calibration value in the
corresponding section
to adjust the reading. Enter a value between
000 to 254 (000 and 128 = no calibration value). When in Celsius,
every value from 001 to 127 adds .5 degrees, and every value from
129 to 254 subtracts .5 degrees, to the temperature display. When in
Fahrenheit, every value from 001 to 127 adds 1 degree, and every
value from 129 to 254 subtracts 1 degree, to the temperature display.