Delay 2
(Addresses 232, 234)
One of two different zone delays (delay 1 & delay 2) can be assigned to each zone. Zones activated at this
address are assigned "Delay 2" definition. The length of zone entry delays is programmed at addresses 248-
249. Any zones that are not activated at addresses 220-232 are assigned "Delay 1" zone definition.
Note:
When more than one zone definition is selected, zone definition priority is assigned in this
order: (1) 24 hr., (2) instant, (3) follow, (4) delay 2 and (5) delay 1.
Bypass-enabled
(Addresses 236, 238)
"Bypass-enabled" zones (keys "on") are zones that can be bypassed during "manual bypass" arming and
auto zone shutdown. The fire zone cannot be bypassed.
Note:
If a zone should not be bypassed, turn "off" its corresponding zone key.
System assignment
(Addresses 240, 242)
Refer to "System Partitioning", page 25)
Related programming: "Partitioning 206, [8]."
Special Timing Functions
3 Digit Decimal Value Programming
Decimal programming is used to program addresses 244 to 255. Values entered must contain 3 digits.
Decimal value programming:
1) Press [
ENTER
] + installer code. ([
ENTER
] key will flash.)
2) Enter 3 digit address (244 to 255).
3) Enter 3 digit DECIMAL value.
4) To erase, press [
CLEAR
]. To save, press [
ENTER
].
5) Repeat from step 2 onward for next address. To exit programming mode press [
CLEAR
].
“No movement”
If a time is programmed at address 253, and a report code is entered at address 190 (SECTION 32), the panel
will send a report to the central, when there is no movement in the protected area for a designated time period.
"Late to close"
If the system is not armed by a specified time (addresses 245, 246) the code programmed at address
190 (SECTION 32) will be transmitted.
Auto arming
The panel can be programmed to automatically arm itself every day in two ways: at the same time pro-
grammed for the auto test report (addresses 245, 246) and/or once the "no movement" delay has
elapsed (address 253). To program "auto arming", go to address 206 and enable key [5] (auto arm on
time), and/or key [6] (auto arm on "no movement"). All zones must be closed in order for the system to
auto arm. If panel fails to auto arm, only the "no movement/late to close" report will be transmitted. The
"auto arm" report is programmed at address 188 (SECTION 32).
Operational note regarding special timing functions
The time programmed at addresses 245, 246 can be used to:
• Specify the time of day for the Test Report (code programmed at address 175 (SECTION 28).
• Transmit the Late to Close/No Movement code (address 190 (SECTION 32) if the system is not armed
by a specified time.
• Auto-arm the system and if programmed, transmit the arming code at address 188 (SECTION 32)
after transmitting the Late to Close/No Movement code (as above).
The amount of time programmed at address 253 (Max = 63.75 hours) can be used to;
• Transmit the Late to Close/No Movement code, address 190 (SECTION 32), if there is no movement in
the protected area while the system is disarmed.
• Auto-arm the system and if programmed, transmit the arming code at address 188 (SECTION 32)
after transmitting the Late to Close/No Movement code (as above).
IM728-738
22