IM728-738
Zone alarm codes:
(Addresses 120-143)
SECTION 15 - 20
Alarm report codes programmed will be sent to the monitoring station, identifying the zones that are gen-
erating alarms.
Zone restore codes:
(Addresses 144-167)
SECTION 21 - 26
Zone restoration codes programmed will be sent to the monitoring station, identifying zones returning to
normal status after alarms.
Trouble codes:
(Addresses 168-175)
SECTION 27 - 28
8 trouble status codes can be reported to the central, if programmed: max. auxiliary current, bell
disconnect/max. bell current, battery disconnected/low voltage, power failure, program change (indicates that
someone has initiated "installer" or Espload programming), timer loss, fire loop trouble, and test report.
(See "Trouble Display/Monitoring", page 27-28, for a list of trouble conditions displayed on the keypad.)
Trouble restore codes:
(Addresses 176-183)
SECTION 29 - 30
If trouble conditions occur and are reported, once normal status is re-established, a "restoration" code
can be transmitted to the central to indicate that the "trouble" situation has been rectified. Note: All
Tamper/Wire Faults must be restored before a restoration code is transmitted.
Special codes:
(Addresses 184-193)
SECTION 31 - 33
These codes are assigned to report 10 special status conditions.
Panic 1
Panic alarm will be reported to the central if keys [1] and [3] are pressed for 2 seconds.
Panic 2
Panic alarm will be reported to the central if keys [4] and [6] are pressed for 2 seconds.
Panic 3
Panic alarm will be reported to the central if keys [7] and [9] are pressed for 2 seconds.
Partial arming
Will be reported to the central if the control panel is armed while any zones are
bypassed or when the system is force armed.
Auto/Espload Arm
Will be reported to the central when Espload is used to arm the control panel or
when the system arms itself automatically (on “no movement” or at a specified time.)
Arm with master code Will be reported to the central when the master code is used to arm control panel.
No movement/
Will be reported to the central when there is no movement in the protected area for
a designated time period, or if the system has not been armed by the required time.
Tamper report
The hexa digit entered for this report code will replace the first digit of all zone alarm
report codes when tamper "trouble" occurs. This identifies zone location of the tam-
per "trouble" to the central (auto-generated codes).
Disarm with Espload Will be reported to the central when Espload is used to disarm the control panel.
Disarm with
Will be reported to the central when master code is used to disarm control panel.
master code
Communicator Formats
(Address 194)
Ademco contact ID
(all codes reported)
(key [10])
All report codes are preprogrammed in this DTMF reporting format. There is no need to program values for
addresses 088 -193 if both central station numbers use this format. Contact ID event codes are listed below:
14
late to close