32 Installer’s Guide
6.6.2 Door Forced Open Feedback
Section [003]: Options [7] and [8]
The Access Alarm can be either audible or silent and will either
beep as long as the Access Alarm is occurring or follow the Beep
Timer in section
[011]
. The sound of the Door Forced Open
Alarm resembles the rapid beep generated during the last ten
seconds of the Exit Delay.
Option
[7]
ON = Door Forced Open Alarm is audible (default)
Option
[7]
OFF= Door Forced Open Alarm is silent
If option
[7]
is enabled:
Option
[8]
ON = Door Forced Open Alarm follows Beep Timer
(section [011])
Option
[8]
OFF= will beep as long as Door Forced Open Alarm is
occurring (default)
6.6.3 Beep Timer For Door Forced Open Alarm
Section [011]
This Beep Timer determines the amount of time the Door Forced
Open Alarm (see section 6.6.2 above) will beep. Enter any value
between 001 and 255 to determine the number of seconds the
Door Forced Open Alarm will beep. (default = 5 seconds)
Section
[003]
Option
[7]
Door Forced Open Alarm (audible/silent)
Option
[6]
Door Forced Open Alarm follows (restore/timer)
[011]
Beep Timer for Door Forced Open Alarm
Содержание Digiplex DGP-641
Страница 1: ...DGP 641 LCD Keypad V1 3 DGP 641ACC Access Control LCD Keypad V1 1 Reference and Installation Manual...
Страница 2: ......
Страница 10: ...8 Installer s Guide Figure 1 Connecting the Keypad and Keypad Zone...
Страница 12: ...10 Installer s Guide Figure 4 Access Control Connections DGP 641ACC Only...
Страница 37: ...Digiplex LCD Keypad 35n Table 2 Special Characters Catalog...
Страница 42: ......
Страница 43: ......
Страница 44: ......