Digiplex LCD Keypad 23
n
6.0 FEATURES FOR DGP-641ACC ONLY
6.1 B
US
V
OLTMETER
The Bus Voltmeter provides a real-time display of the voltage so
you can verify if the bus is supplying sufficient power at the
keypad’s location. The readings will appear on the LCD screen.
A reading of 9.2V indicates that the voltage is too low. This may
occur when too many modules are connected to the bus, a
module is installed too far from the panel or if the system is
running on the battery. In some cases adding an external power
supply may correct the situation.
Step 1: From Normal Mode press and hold the
[0]
key.
Step 2: Enter the
[
INSTALLER
CODE
]
(by default 000000)
Step 3: Press
[
ACC
]
The voltage may drop during the control panel battery
test.
6.2 A
SSIGNING
D
OORS
T
O
P
ARTITIONS
Section [001]: Options [5] to [8]
Although the keypad can be programmed to display the status of
various partitions, the Access Control door can be assigned to
one or more partition(s) in the alarm system. This means that the
actions performed with the Access Control Card will be directly
linked to the partition(s) assigned to that door. For example, the
keypad is assigned to all four partitions (see section 4.1 on
page14), but the door is assigned to Partition 2. When the user
presents the Access Control Card to the door's reader to arm the
Содержание Digiplex DGP-641
Страница 1: ...DGP 641 LCD Keypad V1 3 DGP 641ACC Access Control LCD Keypad V1 1 Reference and Installation Manual...
Страница 2: ......
Страница 10: ...8 Installer s Guide Figure 1 Connecting the Keypad and Keypad Zone...
Страница 12: ...10 Installer s Guide Figure 4 Access Control Connections DGP 641ACC Only...
Страница 37: ...Digiplex LCD Keypad 35n Table 2 Special Characters Catalog...
Страница 42: ......
Страница 43: ......
Страница 44: ......