24 Installer’s Guide
partition, only Partition 2 will arm.
Option
[5]
ON = door assigned to Partition 1(default)
Option
[6]
ON = door assigned to Partition 2
Option
[7]
ON = door assigned to Partition 3
Option
[8]
ON = door assigned to Partition 4
OFF
= Access Control Cards will not be able to arm and/or
disarm partitions from the door's reader.
6.3 R
EADER
’
S
O
PTIONS
6.3.1 Reader’s LED To Follow Partition’s Status
Section [002]: Option [6]
The reader's LED can be programmed to flash according to the
partition's status. When this feature is enabled, the reader’s red
LED will flash when the partition is arming, in Exit Delay, in Entry
Delay, in Burglar Alarm or in Fire Alarm.
Option
[6]
ON = LED follows the door’s partition status. (default)
Option
[6]
OFF= The reader's LED will not flash.
6.3.2 Reader’s Beep To Follow Partition's Status
Section [002]: Option [7]
This feature will only function when section
[002]
option
[6]
is
enabled. The reader can be programmed to beep according to its
keypad's beep when the partition assigned to the door is arming,
in Exit Delay, in Entry Delay, in Burglar Alarm, or in Fire Alarm.
Option
[7]
ON = Beep follows the partition's status. (default)
Option
[7]
OFF= The beep will not follow the partition's status.
Содержание Digiplex DGP-641
Страница 1: ...DGP 641 LCD Keypad V1 3 DGP 641ACC Access Control LCD Keypad V1 1 Reference and Installation Manual...
Страница 2: ......
Страница 10: ...8 Installer s Guide Figure 1 Connecting the Keypad and Keypad Zone...
Страница 12: ...10 Installer s Guide Figure 4 Access Control Connections DGP 641ACC Only...
Страница 37: ...Digiplex LCD Keypad 35n Table 2 Special Characters Catalog...
Страница 42: ......
Страница 43: ......
Страница 44: ......