K4461-1V1 4/05 Rev. A
ADEMCO 6150RF
Keypad/Transceiver
USER GUIDE
Keypad Features
DISPLAY
The keypad features a 2-digit numeric display for zone identification and pre-designated English-
language prompts (e.g., “ALARM,” “AWAY,” “STAY,” “CHECK,” etc.) for indicating system status.
See
Figure 1.
FUNCTION KEYS
The function keys are located behind a decorative door and are continuously backlit for ease in use.
(Check the User’s Guide that accompanies the control panel for detailed instructions on the use of these
keys.)
The function keys include keys for panic alarm activation. The panic alarms are activated by pressing
key pairs [1] & [*], [3] & [#], or [*] & [#], or a Special Function Key (see below). Whether these panic keys
function and the type of panic alarms they produce is determined by the control panel’s capability and
programming.
(Check with your installer for the availability and type of alarm of these panic keys.)
SOUNDER
The sounder is a piezo-electric sounder that pulses for fire alarms and generates a two-tone sound for
burglary and audible panic alarms.
KEYPAD LEDS
The keypad contains two LEDs that indicate the status of the system as follows:
LED Function
Green
Lights when the system is ready to arm (no zone faults are present).
Red
Lights when the system is armed.
SPECIAL FUNCTION KEYS
These are four keys located to the left of the numeric keys (see
Figure 1
). The keys may be programmed
by your installer for panic alarms or other special functions such as macros (a frequently used series of
key entries).
Function keys must be held down for at least 2 seconds to activate an alarm.
(Check with your installer for the programmed function of these keys.)
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
ARMED
READY
6150RF-00-001-V1
Figure 1: ADEMCO 6150RF Keypad/Transceiver with Front Door Removed