background image

1

Controllers

INSTALLATION INSTRUCTIONS

• The 598 is an eight button, momentary, dry contact keypad.  It is normally used in conjunction with the

Xantech 590 Programmable Controller as shown in the illustration below.

• Requires 9-conductor cable, as shown.  Use 24 gauge, stranded or solid wire, up to lengths of 5000'.

• Two 598's may be used to provide momentary switch closures for all 16 of the 590 input terminals.

• Two or more 598's may also be wired in parallel to the same terminals on the 590 where control from more

than one room or area is required.

• The 598 fits into a standard single-gang J-box.  598's may also be used side-by-side in two (or more) gang

J-boxes.

• A legend cutout sheet (included) contains typical component function command icons for button

identification.

598-00

EIGHT BUTTON DRY CONTACT KEYPAD

C

1
2
3
4
5
6
7
8

1

12VDC

12VDC

1 2 3 4

BANK

RES DEL SEQ PGM

+

2

3

4

5

6

7

8

9 10 11

14 15 16 O G

+

12 13

Emitter, Connecting Block, etc.

To 120 V AC

Unswitched

786-00

Power

Supply

White Striped
Side (output)

Wire size typically AWG 20-24

Model 590

(rear panel)

Model 598

Key Pad

(rear view)

ON

Ground or "

"

return wires.

+12V DC

5-14-99