![PARADOX INSIGHT HD77 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/paradox-insight/hd77/hd77_installation-manual_753662006.webp)
LED Status Indicators
6
LEDs 1, 2, 4, and 5 are installer diagnostic indicators that are active when the lock mechanism is open. LED 3
displays various system functionalities. The following table displays the HD77 camera LED status indicator
functionality.
Note:
For
LED 3
:
•
The PIR indicator can be set On/Off by the installer
•
The VOD indicator can only be turned-off by the master user using the Paradox Insight™ application.
IMPORTANT: Turning the VOD indicator off may be considered a violation of applicable laws in
some countries. Install the HD77 camera according to local laws.
Table 1: LED Assignment
LED
Functionality
LED Display
LED 1
Digiplex Data TX
Flashing green: Data transmission
Off: No data transmission
LED 2
Digiplex Data RX
Flashing green: Data reception
Off: No data reception
LED 3
(with front
cover locked
or un-locked)
•
HD77 camera is powered-up and functioning. There are
currently no PIR detections or VOD streaming
•
Unit has no power
Off
Firmware upgrade in progress.
Flashing purple
VOD Blue
on
Power-up Flashing
blue
Locate mode
Flashing blue
General Combus failure, wiring or communication problem
Flashing red
Bus low power
Flashing red
PIR detection
Red on for 3 seconds
LED 4
Active Web connection
Green on
LED 5
LAN 10/100Mb link
LAN 10100Mb data TX or RX
Green on: LAN active
Off: No connection
Flashing green: Data transfer
Flashing red: UPnP failure
Содержание HD77
Страница 1: ......
Страница 4: ...4 ...
Страница 18: ...Mounting the HD77 18 Mounting the HD77 Camera on a Wall or Corner ...
Страница 40: ...Verifying HD77 Camera Functionality 40 Configuring PIR Settings with Keypads ...
Страница 44: ...Deleting a HD77 Camera from ParadoxMyHome 44 ...
Страница 46: ...46 Figure 3 BabyWare Home Window ...
Страница 50: ...50 ...
Страница 54: ...54 ...
Страница 68: ...68 ...