Quantum and Evolution Series Installation and Operating Handbook
7-69
Edit-Tx-Carrier-Advanced-AUPC-Eb/No Screen
Units:
dB
Minimum value:
0.1
Maximum value:
14.9
Step size:
0.1
Factory default:
10.0
Description:
This is the distant Eb/No that AUPC tries to maintain by adjusting the Tx
power level.
Edit-Tx-Carrier-Advanced-AUPC-Power Offset Screen
Units:
dBm
Minimum value:
0
Maximum value:
25
Step size:
0.1
Factory default:
1
Description:
This is the maximum increase in Tx power level that AUPC is allowed to
make to maintain distant Eb/No.
Target remote EbNo:0.1 to 14.9dB
[3.1] Step 0.1dB
New: 3.1
Max power offset:0 to 25dBm
[1.0] Step 0.1dBm
New: 1.0