Quantum and Evolution Series Installation and Operating Handbook
7-145
Units:
Minimum value:
9.9E-15
Maximum value:
1.0E-2
Step size:
0.1E1
Factory default:
1E-4
Description:
Sets the error-rate threshold above which a deferred alarm will be
generated. This alarm can be switched off or on using the
BER threshold
alarm
option of the
Edit-Unit-Advanced-Alarms-Actions
menu.
Edit-Unit-Advanced-Alarms-Thresholds-Rx Eb/No Deferred Alarm Threshold Screen
Units:
dB
Minimum value:
0.0
Maximum value:
99.0
Step size:
0.1
Factory default:
3.0
Description:
Sets the Eb/No threshold below which a deferred alarm will be
generated.
Edit-Unit-Advanced-Alarms-Thresholds-Buffer Slip Deferred Alarm Screen
EbNo threshold:0 to 99dB
[03.0] Step 0.1dB
New: 03.0
Buf slip threshold:0 to 9999hrs
[0000] Step 1hrs
New: 0000