Quantum and Evolution Series Installation and Operating Handbook
7-26
Options:
Ignore CRC
Specifies that the terrestrial G.732 frame does not contain a checksum
or
it should be ignored.
Check CRC
Specifies that the terrestrial G.732 frame does contain a checksum that
should be checked for errors. If enough errors accumulate then a Tx Drop
MUX BER alarm will be raised (
‘Input BER > 1E-3’
).
Factory
default:
Ignore CRC
Description:
This option is applicable only with G.732 Drop/Insert bearers and
controls the processing of any terrestrial checksum.
Edit-Tx-Baseband-Advanced-Framing-CRC-Frame Re-acquisition Screen
Frame re-acquisition on CRC loss:
[Normal]
New: Normal
Содержание Quantum
Страница 36: ...Quantum and Evolution Series Installation and Operating Handbook 7 7 7 3 2 Status Menu Front Panel Status Menus...
Страница 112: ...Quantum and Evolution Series Installation and Operating Handbook 7 83 7 3 3 2 Edit Rx Menu Front Panel Edit Rx Menus...
Страница 150: ...Quantum and Evolution Series Installation and Operating Handbook 7 121...
Страница 258: ...Quantum and Evolution Series Installation and Operating Handbook 8 32 Eb NoExplanatory Diagram...
Страница 342: ...Quantum and Evolution Series Installation and Operating Handbook 13 14 13 18 Performance Graphs...
Страница 348: ...Quantum and Evolution Series Installation and Operating Handbook 13 20 Modem Error Probability versus Eb No 16QAM Turbo...