Quantum and Evolution Series Installation and Operating Handbook
7-133
The effect of
Link-Remote
is to loop back whatever is received over the
modem’s satellite ESC channel to the modem’s M&C port and to
transmit over the satellite ESC channel whatever is transmitted by the
modem out of its M&C port.
IP to Serial
supports the transmission of IP-wrappered RS485 messages
through the ESC channel, which are then transmitted as serial messages
on the remote RS485 bus.
Edit-Unit-Interface-Aux Interface Screen
Options:
RS232
RS422
RS485
IP
Factory default:
RS232
Description:
Specifies the Aux electrical interface. Note RS485 is not available on the
IDR card. The relevant physical interface (on the shared Async ESC/Auc
port on the base modem or the separate Aux port on the IDR card) is
directly connected through to the ESC channel.
Aux interface: [RS485]
1:RS232 2:RS422
3:RS485
4:IP