BA_PH_690-100_EN_10-22.docx
50
16.1.3
Tele-Digit Components
Figure 52: Tele-Digit components
No.
Description
No.
Description
1
Slider
6
Clamping lever “Pull
-
out”
2
Pull-out
7
Cover for battery compartment
3
Flip stop “Slider”
8
Fine adjustment wheel
4
Flip stop “Pull
-
out”
9
End stop screw “Slider”
5
Clamping screw “Slider”
10
End stop screw “Pull
-
out”
16.1.4
Digital Indicator
Figure 53: Digital indicator
Pos.
Description
A
Switchover Slider or Pull-out
B
Function key (depending on mode)
C
Function key (depending on mode)
S
Symbols Slider 1 / Pull-out 2 active
16.1.5
Length Measurement Switching
Switching between the two length measurements
1
(slider) and
2
(pull-out) is done with button
A
.
→
The currently active length measurement is shown in the top line of the LCD display.
16.1.6
Calibrate Tele-Digit
•
Move the pull-out (
3
) all the way to the right against the end stop screw (
10
) and clamp it with lever (
6
).
•
Move slider (
1
) all the way to the right against end stop screw (
9
) and clamp with clamping screw (
5
).
•
Open battery compartment (
7
) and remove one of the batteries (power supply off).
•
Now reinsert the battery (power supply back on).
→
The system now automatically calibrates itself and the stored reference dimensions appear again.
•
The calibration procedure is completed.
For checking purposes, you can now perform test cuts for both flip stops at any position and check the cut
dimensions for consistency. If there are any dimensional deviations, the reference values for the flip stop posi-
tions must be redefined (procedure see chapter
2
4
8
7
1
X
Y
5
6
3
Y
X
9
10
Schieber
Auszug
C
B
A
1
2
1 2
S
Slider