BA_PH_690-100_EN_10-22.docx
45
13.5.2
Calibrate Angle
•
Move the saw blade set to 0° to the uppermost position
•
Then switch off the main switch and secure or lock it.
•
Use a 90° stop angle to check that the saw blade is square.
•
If an angular gap appears here, the angular axis must be calibrated.
→
Switch on the main switch and correct the angle via the positioning
keys until the angle gap has completely disappeared again. In the 0°
position, the saw blade is then exactly 90.0° to the table top.
→
In the overview
“
Machine >> Angle
”
(see
Figure 38) a value
deviating from 0.0° now appears (e.g. 0.4°).
Figure 39: Angular gap
Figure 40: Calibrate angle
1.
Touch the value field “
Calib. angle
”
→
The keyboard (see figure above right) appears.
2.
Enter the reference angle
0.0°
for the saw blade here.
Note:
If 0.0° is already entered here, no entry is necessary.
3.
Confirm with
“
ENTER
”
→
The correct 0° position is adopted into the “
Calib. angle
” field
:
Figure 41: Adopt calibration value for angle
4.
Press the “Set" button to reference the value in the “
Calib. angle
” field
.
→
As confirmation, the display jumps back to the overview (see
→
The calibration procedure for the saw blade angle is completed.
Angular gap
1.
2.
3.
4.