BA_PH_680-200_EN_11-22.docx
54
17.3
Calibrate Saw Blade Height and Angle
By re-sharpening the saw blades or inserting other resp. new saw blades, it is necessary to calibrate the control
unit to the respective saw blade.
17.3.1
Calibrate Angle
1.
Move the saw blade to the uppermost position via value input.
2.
Turn off the main switch and lock it. Check that the saw
blade is square with a 90° angle stop (Figure 58). Use the
table top as reference surface.
3.
Turn on the main switch and correct the possible angular gap
by means of value input or manual inching mode until the
angular gap has completely disappeared (= 90,0°).
4.
In the “
Angle
” window, select the button
(
Figure 56) and enter the value 0.00. Confirm with .
5.
Then save the value with .
6.
The procedure is completed.
Figure 58: Angular gap
Figure 59: Calibrate angle
Figure 60: Calibrate height
17.3.2
Calibrate Height
First turn off the main switch on the control cabinet and lock it with a padlock. Turn the stationary saw blade by
hand so that one saw tooth is exactly in the centre of the axis and its cutting surface is at a 90° angle to the table
top of the machine (see
Figure 62 on the next page).
1.
Position the saw blade angle to 0° via the value input.
2.
Move the saw blade height to the position 50.0 mm by
using the value input or manual inching (section
in combination with a suitable measuring device (e.g.
depth caliper).
3.
In the “
Height
” window, select the button
(
Figure 54) and enter the value 50.00.
Then confirm this value with .
4.
Then save the value with .
5.
The procedure is completed.
Figure 61: Set saw blade height to 50.0 mm.
Angular gap
50.0 mm