87
4
●
EXT (External) Timing Select
This table permits the sequence dwell time on the selected monitor to be synchronized with the time lapse mode set in the
associated Time Lapse VCR.
To program or edit the EXT Timing Select Table, do the following:
1. Move the cursor to position 3 by moving the Joystick Controller, then press the
CAM (SET)
key.
2. Move the cursor to the desired monitor position by moving the Joystick Controller.
Press the Function
F4
button to open the Pop Up Window. Select EXT On or Off by moving the Joystick Controller, and
then press the
CAM (SET)
key to execute the selection.
3. When satisfied with all settings, press the
MON (ESC)
key to escape from the programming mode.
The cursor returns to position 3.
Note:
If External Timing is selected for a monitor, any Dwell Time programmed on the sequence tables for that monitor will be
invalid.
Minimum duration for camera switching pulse is one (1) second.
S e t
U p
E X T
F 1 : - -
F 2 : - -
F 3 : - -
F 4 : P o p
E X T .
M O N I
0 1
S y s t e m
T i m i n g
S e l e c t
E X T
T i m i n g
0 2
0 3
0 4
0 5
0 6
0 7
0 8
0 9
1 0
1 1
1 2
1 3
1 4
1 5
1 6
O n
o f f
O n
O n
o f f
o f f
o f f
o f f
o f f
o f f
o f f
o f f
o f f
o f f
o f f
o f f
U p
q
w
e
Содержание WVCU550C - SYSTEM CONTROLLER UNIT
Страница 8: ...9 1 SECTION 1 FEATURES OF THE SYSTEM 500 MATRIX SWITCHER ...
Страница 19: ...21 2 SECTION 2 DETAILED PRODUCT DESCRIPTION AND SELECTION ...
Страница 45: ...47 3 SECTION 3 INSTALLATION AND SYSTEM CONNECTIONS ...
Страница 61: ...65 4 SECTION 4 SOFTWARE SETUP ...
Страница 90: ...95 5 SECTION 5 OPERATING PROCEDURES ...
Страница 122: ...127 6 SECTION 6 TROUBLESHOOTING ...
Страница 126: ...131 7 SECTION 7 SPECIFICATIONS ...