39
2
WV-PB5564 Alarm Board
■
Appearance
q
Alarm Number Display
Indicates the alarm input number when an alarm is received from the associated alarm
sensor.
Note:
The display indicator lights up as shown below when the alarm number is over
one hundred.
ALARM
TEST
1-32
5
RESET
MODE
33-64
q
w
e
r
t
Indicator
w
Mode Selection Switch (MODE)
This rotary switch, in combination with the Test button, is used to select the alarm test
mode.
Mode 0:
Press the Test button to receive an alarm number display in chronological
order from the internal memory which stores all alarms received from the Alarm
Input Ports.
Mode 1:
Press the Test button to simulate receiving alarm inputs 1-64 in ascending
order, one alarm per second.
Use this mode to test the system for Alarm Mode-1, Mode-2 or Mode-3 setup.
Mode 2:
Press the Test button to simulate receiving alarm inputs 1-64 all at the same
time.
Use this mode to test the system for Alarm Mode-1, Mode-2 or Mode-3 setup.
Mode 3-9:
These modes are not available.
Note:
Alarm inputs 65-128 are activated in the above modes if SW1 on the board is set
to Board Number 2. Refer to the Board Setting on page 41.
e
Test Button (TEST)
This button is used to run the alarm test mode in combination with the Mode Selection
Switch.
r
Reset Button (RESET)
Resets the alarm test mode or clears alarm records from the internal memory.
Содержание WVCU550C - SYSTEM CONTROLLER UNIT
Страница 8: ...9 1 SECTION 1 FEATURES OF THE SYSTEM 500 MATRIX SWITCHER ...
Страница 19: ...21 2 SECTION 2 DETAILED PRODUCT DESCRIPTION AND SELECTION ...
Страница 45: ...47 3 SECTION 3 INSTALLATION AND SYSTEM CONNECTIONS ...
Страница 61: ...65 4 SECTION 4 SOFTWARE SETUP ...
Страница 90: ...95 5 SECTION 5 OPERATING PROCEDURES ...
Страница 122: ...127 6 SECTION 6 TROUBLESHOOTING ...
Страница 126: ...131 7 SECTION 7 SPECIFICATIONS ...