33
Configure the settings relating to Panasonic alarm protocol
Click the [Notification] tab on the "Alarm setup" page. (
☞
page 15)
■
Panasonic alarm protocol setup
The settings relating to Panasonic alarm protocol can be configured on this page.
[Panasonic alarm protocol]
Select "ON" or "OFF" to determine whether or not to
notify of an alarm occurrence by Panasonic alarm proto-
col when an alarm is detected.
Default setting:
OFF
Note:
When "ON" is selected, the alarm occurrence will be
notified to the registered destination IP addresses in
order (to IP address 1 first, to IP address 8 last).
[Destination port]
Select a destination port of the Panasonic alarm proto-
col from the following.
Available value:
1 - 65535
Default setting:
1818
[Retry times]
Select a retry time of Panasonic alarm protocol.
Available value:
1 - 30
Default setting:
2
■
Panasonic alarm protocol
[Destination IP address]
Enter the destination IP address of the Panasonic alarm
protocol from the following. Host name is unavailable for
the IP address. Up to 8 destination addresses can be
registered.
To notify by Panasonic alarm protocol when an alarm
occurred, check the "Alarm" checkbox respective to the
desired address.
To provide notification using Panasonic alarm protocol
when any of the following has occurred, check the
"Diag." checkbox respective to the desired address.
• When notification of the remaining space of the SD
memory card has been provided (
☞
page 19)
• When the SD memory card has become full
• When mounting of the SD memory card has failed
To delete the registered address, click the [DEL] button
respective to the desired address.
Important:
Confirm that the destination IP addresses are regis-
tered correctly. When a registered IP address does
not exist, notification may be delayed.