56
DP-2330/3030
MAR 2005
Ver.2.1
DP-2310/3010
(11) Disconnect the
Harness
.
(12) Loosen the
Process Unit Screw
(743).
(13) Slide the
Process Unit
out.
Caution:
To prevent damage to the Process Unit, ensure
the Right Cover is still open before pulling the
Process Unit out.
Caution:
Exercise caution not to scratch the surface of the
OPC Drum
(Green), and not to touch it with bare
hands.
Caution:
The OPC Drum is sensitive to light. To prevent
optical exposure problems, do not expose the
OPC Drum to direct sunlight or bright light (even if
it is a 1000-Lux fluorescent lamp).
(14) Remove 1
Screw
(1Y).
(15) Remove the
Front Lock Plate Assembly
(751)
(longer plastic tab).
(16) Remove 1
Screw
(1Y).
(17) Remove the
Rear Lock Plate Assembly
(752)
(shorter plastic tab).
(18) Turn the
OPC Drum Assembly
in the direction
of the arrow and remove.
Caution:
Exercise caution not to scratch the surface of the
OPC Drum
(Green), and not to touch it with bare
hands.
Содержание Workio DP-3030
Страница 4: ...4 Beispiel DP 2330 3030 Hinweis...
Страница 8: ...8 memo...
Страница 35: ...35 DP 2330 3030 MAR 2005 Ver 2 1 DP 2310 3010 1 6 Control Panel DP 2310 3010 DP 2330 3030...
Страница 70: ...70 DP 2330 3030 MAR 2005 Ver 2 1 DP 2310 3010 23 Remove 3 Screws 19 24 Remove the Motor Bracket 908...
Страница 454: ...memo...
Страница 455: ...88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 DZSD001829 9...
Страница 470: ...memo...
Страница 471: ...Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 DZSD000965 14...
Страница 482: ...Local Firmware Update Tool Parallel USB Port 5b4 Firmware Code File selection is completed Click Next Page 12...
Страница 486: ...DZZSM00270...