104
DP-2330/3030
MAR 2005
Ver.2.1
DP-2310/3010
3.7.7.
Notice after installing the HDD option
After the Hard Disc Drive Unit is installed, to prevent a Disc Scan Function from being performed (similar
to Windows OS when the power is abruptly interrupted), it is important to follow the step sequence below
when turing OFF the Power Switches on the machine.
1. Turn the Power Switch on the left side of the machine to the OFF position first.
2. Wait approximately 10 seconds while the machine writes the closing status onto the Hard Disc Drive
Unit.
3. Turn the Main Power Switch on the back of the machine to the OFF position.
3.7.8.
Firmware Emergency Recovery
The easiest method to recover the firmware in an Emergency Recovery routine is to either use the Local
Firmware Update Tool software by selecting the Independent File method, or using the Master Firmware
Flash Card method (3 Flash Cards required).
Whichever method you select, it is easier to restore the machine's firmware to the Standard (AAV) Type
first as it only requires 3 files to bring the machine to initial working condition. (Install the files in this
order: SC, SPC and PNL).
After recovering, if optional PCL or PS/PCL firmware is required, use the Network Firmware Update Tool
or the Local Firmware Update Tool to update the firmware to the required level.
If the unit does not boot up properly, follow the steps below:
1. Turn the power Off (use the power switch on the back of the unit, not the side of the unit).
- Before proceeding to the next step, you must prepare either the Local Firmware Update Tool or
create the Master Firmware Flash Cards (read the appropriate sections first).
- If using the Master Firmware Card, insert the Master Firmware Flash Cards in the unit.
2. Turn the power On while holding the [ENERGY SAVER] button.
3. When the green lamp on the front panel turns On, release the [ENERGY SAVER] button.
- If using the Master Firmware Card, the unit will start updating the Firmware code files
automatically.
The unit is now ready to accept the firmware code from the USB Port or Master Firmware Card.
Repeat the above steps if there are additional firmware code files to be updated.
Содержание Workio DP-3030
Страница 4: ...4 Beispiel DP 2330 3030 Hinweis...
Страница 8: ...8 memo...
Страница 35: ...35 DP 2330 3030 MAR 2005 Ver 2 1 DP 2310 3010 1 6 Control Panel DP 2310 3010 DP 2330 3030...
Страница 70: ...70 DP 2330 3030 MAR 2005 Ver 2 1 DP 2310 3010 23 Remove 3 Screws 19 24 Remove the Motor Bracket 908...
Страница 454: ...memo...
Страница 455: ...88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 DZSD001829 9...
Страница 470: ...memo...
Страница 471: ...Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 DZSD000965 14...
Страница 482: ...Local Firmware Update Tool Parallel USB Port 5b4 Firmware Code File selection is completed Click Next Page 12...
Страница 486: ...DZZSM00270...