83
DP-2330/3030
DEC 2004
Ver. 2.0
DP-2310/3010
2.
Output Check
Press the "START" key to start and press the "STOP" key to reset.
F4 Mode (Output Check)
No.
Item
Function
Remark
040 Total Counter
When SPC PCB CN715-8 signal
level changes to 0V from +24V,
count up the Total Counter.
041 Key Counter / Card Counter
When SPC PCB CN726-2 signal
level changes to 0V from +24V,
count up the Key Counter.
When SPC PCB CN726-6 signal
level changes to 0V from +5V, count
up the Card Counter.
042-
049
Not Used
050 Main Motor
When SPC PCB CN723-2 signal
level changes to 0V from +5V, the
Main Motor activates.
051 Toner Bottle Motor Rotation In
Forward Direction
When SPC PCB CN720-16 signal
level changes to 0V from +24V, the
Motor rotates in the forward
direction.
052 Toner Supply Clutch
When SPC PCB CN720-18 signal
level changes to 0V from +24V, the
Clutch activates.
053 LSU Fan / Power Supply Fan /
Book Fan
When SPC PCB CN704-10 is 24V,
LSU Fan rotation is high-speed.
When SPC PCB CN704-9 is 24V,
Power Supply Fan rotation is
high-speed.
When SPC PCB CN709-16 is 24V,
Book Fan rotation is high-speed.
054 Density Sensor Solenoid
When SPC PCB CN714-6 signal
level changes to 0V from +24V, the
Solenoid activates.
055 Not Used
056 Fuser Fan
When SPC PCB CN709-13 is 24V,
Fuser Fan rotates.
057 Not Used
058 Fuser Web Solenoid
When SPC PCB CN721-12 signal
level changes to 0V from +24V, the
Solenoid activates.
059-
060
Not Used
061 Registration Clutch
When SPC PCB CN715-2 signal
level changes to 0V from +24V,
clutch operates.
1 minute
062 Not Used
063 Paper Feed Roller Clutch
(1st Paper Tray)
When SPC PCB CN715-4 signal
level changes to 0V from +24V,
clutch operates.
1 minute