64
DP-2330/3030
DEC 2004
Ver.2.0
DP-2310/3010
E3: Development System Error
Code
Function
Possible Cause(s)
E3- 01 Toner Bottle Motor Rotation
1. Toner Bottle Motor connector disconnected.
2. Toner Bottle Motor defective.
3. Toner Bottle Motor Drive Mechanism defective.
4. Toner Bottle installed incorrectly.
5. SPC PCB connector disconnected.
6. SPC PCB defective.
7. Toner Bottle Home Position Sensor connector
disconnected.
8. Toner Bottle Home Position Sensor defective.
E3- 03 Toner Density Sensor Gain
1. Sensor connector disconnected.
2. Sensor defective.
3. SPC PCB connector disconnected.
4. SPC PCB defective.
E3- 20 Main Motor Rotation
1. Drive Mechanism defective.
2. Main Motor connector disconnected.
3. Main Motor defective.
4. SPC PCB connector disconnected.
5. SPC PCB defective.
6. LVPS defective.
E3- 40 Copy Density Sensor Output
Adjustment
1. CDS PCB connector disconnected.
2. CDS PCB defective.
3. SPC PCB connector disconnected.
4. SPC PCB defective.
E4: Fuser Unit Error
Code
Function
Possible Cause(s)
E4- 01 Fuser Warm-up Temperature
1. Fuser Thermistor dirty.
2. Thermistor position incorrect.
3. Thermistor defective.
4. Thermistor connector disconnected.
5. Fuser Lamp connector disconnected.
6. Fuser Lamp defective.
7. Fuser Thermostat defective.
8. Thermal Fuse defective.
9. ACD PCB connector disconnected.
10. ACD PCB defective.
11. NFL PCB connector disconnected.
12. NFL PCB defective.
13. SPC PCB connector disconnected.
14. SPC PCB defective.
15. Fuser temperature low. (Adjust F6-31)
E4- 02 Fuser Paper Jam
1. Paper Jam in Fuser Unit.
2. Paper Exit Sensor 1 or 2 disconnected.
3. Paper Exit Sensor 1 or 2 defective.
4. SPC PCB connector disconnected.
5. SPC PCB defective.