97
DP-2330/3030
DEC 2004
Ver. 2.0
DP-2310/3010
81
QUANTUM Halftone Read
Value of QUANTUM Laser duty of Check
pattern.
+127 - +255
(Read Only)
82
QUANTUM Black Read
Value of QUANTUM Laser duty of Black
pattern.
+127 - +255
(Read Only)
83
Temperature Sensor Value
Value of Temperature sensor.
0 - 255
(Read Only)
84
Humidity Sensor Value
Value of Humidity sensor.
0 - 255
(Read Only)
85
Not Used
86
ADF Reverse Stop Posi.
Adjustment of ADF reverse stop position.
-99 - +99
0.3mm
87
ADF Exhaust Stop Posi.
Adjustment of ADF exit stop position
-99 - +99
0.3mm
88-89 Not Used
90
ADF Read Main Scan Pos.
Adjustment of ADF horizontal image read
start position.
-99 - +99
0.05mm
91
Original Read Edge ADF
Adjustment of original detection timing.
-99 - +99
0.3mm
92
Original Trail Edge ADF
Adjustment of trail edge detection timing.
-127 - 127
0.3mm
93
ADF 100% Image 1-Sided
Adjustment of magnification for 1-sided.
-9 - +9
0.1%
94
ADF 100% Image 2-Sided
Adjustment of magnification for 2-sided.
-9 - +9
0.1%
95
Manual Photo Adj.
Adjustment of Gamma Table Value for Photo
Mode (QUANTUM OFF)
+1 - +5
96
Manual Halftone Adj.
Adjustment of Laser duty of Check pattern for
Text and Text/Photo Mode. (QUANTUM OFF)
+127 - +255
97
Manual Black Adj.
Adjustment of Laser duty of Black pattern for
Text and Text/Photo Mode. (QUANTUM OFF)
+127 - +255
98
Not Used
99
F5/F6 Initialization
Initialize F5/F6 parameter settings.
F6 Mode
No.
Item
Remarks
Setting
Range