4.3.18. Print Skew Adjustment for Platen Glass Scanning
Follow the procedures below to adjust for the skewing when scanning original(s) from the Platen Glass.
Remove the
Platen (L) Glass
. (Refer to 2.2.4.)
<Adjustment 1>
When the printed image is skewed as illustrated.
(1) Mark the original positions of the Screw A and B
before making any adjustments.
(2) Rotate the Screw A counter-clockwise and
Screw B clockwise by the
same amount
.
(Half rotation of the screw, adjusts the skewed
image by approximately 0.9 mm.)
Caution:
Do not rotate the screw by more than half a
rotation.
(3) Make a copy to confirm the correction.
When the printed image is skewed as illustrated.
(4) Rotate the Screw A clockwise and Screw B
counter-clockwise by the
same amount
.
(Half rotation of the screw, adjusts the skewed
image by approximately 0.9 mm.)
Caution:
Do not rotate the screw by more than half a
rotation.
(5) Make a copy to confirm the correction.
Document Leading Edge
< Example of Printed Image >
A
Document Leading Edge
< Example of Printed Image >
A
Содержание Workio DP-1520P
Страница 98: ...98 SEP 2004 Ver 1 2 DP 1520P 1820P 1820E DETAIL A 28 35 31 32 33 34 30 29 ...
Страница 464: ...464 SEP 2004 Ver 1 2 DP 1520P 1820P 1820E memo ...
Страница 465: ...88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 DZSD001829 9 ...
Страница 480: ...Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 DZSD000965 14 ...
Страница 491: ...Local Firmware Update Tool Parallel USB Port 5b4 Firmware Code File selection is completed Click Next Page 12 ...
Страница 495: ...memo ...
Страница 496: ...DZZSM00257 ...