![Panasonic WJSX550C - MATRIX SWITCHER Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/panasonic/wjsx550c-matrix-switcher/wjsx550c-matrix-switcher_operating-instructions-manual_3744146059.webp)
61
3
●
Indirect Connection between the Data Board and Camera Controllers (“Daisy-Chain” Type Wiring)
In this type of connection only one control cable directly connects between Data Connector #1 and Camera Controller #1. The
rest of the Camera Controllers connect to Camera Controller #1 in a Daisy-Chain connection. Refer to the connections and set-
tings shown below.
4-Line (Full Duplex) Connection
TXD
TB
RA (+)
RB
GND
RXD
TA (+)
DATA
(RS485)
A
T
B
1
A
R
B
G
A
T
B
2
A
R
B
G
A
T
B
3
A
R
B
G
A
T
B
4
A
R
B
G
A
T
B
5
A
R
B
G
A
T
B
6
A
R
B
G
A
T
B
7
A
R
B
G
A
T
B
8
A
R
B
G
R(A)
R(B)
GND
T(A)
T(B)
GND
S W
SW100, 150, 200, 250
300, 350, 400, 450
FULL: 4 lines
(Internal Switch: SW5, 4 lines)
TA (+)
TB
RA (+)
RB
GND
1
2
3
4
5
8
Combination
Camera
Reciver
R(A)
R(B)
GND
T(A)
T(B)
GND
R(A)
R(B)
GND
T(A)
T(B)
GND
R(A)
R(B)
GND
T(A)
T(B)
GND
R(A)
R(B)
GND
T(A)
T(B)
GND
R(A)
R(B)
GND
T(A)
T(B)
GND
Note:
Do not use the Camera Status Display described on page 113 in a daisy-chained system as it will not be displayed
correctly.
Содержание WJSX550C - MATRIX SWITCHER
Страница 8: ...9 1 SECTION 1 FEATURES OF THE SYSTEM 500 MATRIX SWITCHER ...
Страница 19: ...21 2 SECTION 2 DETAILED PRODUCT DESCRIPTION AND SELECTION ...
Страница 45: ...47 3 SECTION 3 INSTALLATION AND SYSTEM CONNECTIONS ...
Страница 61: ...65 4 SECTION 4 SOFTWARE SETUP ...
Страница 90: ...95 5 SECTION 5 OPERATING PROCEDURES ...
Страница 122: ...127 6 SECTION 6 TROUBLESHOOTING ...
Страница 126: ...131 7 SECTION 7 SPECIFICATIONS ...