Symptom: The Alarm does not work.
1. Check that the Alarm Mode is set to "Mode 1 - 3" or Timer on the Alarm Mode Select Menu of the Setup Menu.
2. Check that the Alarm Input (Site or Board) is set to "On" on the Alarm Mode Select Menu of the Setup Menu.
Symptom: The sequence does not stop after the programmed time.
1. A timer activated sequence will continue beyond the stop time until the next automatic or manual operation is per-
formed.
Symptom: The Group Sequence does not run to synchronized on the monitors that is made the EXT Timing setting
from the connected VCR.
1. A Group Sequence synchronizes with the EXT Timing on a lowest number of monitor that is assigned to run the
sequence of group monitors.
Symptom: Can’t operate the cameras by the Camera Position Numbers.
1. Check that the CAM-P Mode is set to “On” mode in the CAM-P Menu on the LCD display.
2. Check that the Camera Position Numbers are registered correctly by using the Camera Position Test Mode in the
CAM-P Menu on the LCD display.
Содержание WJSX550C - MATRIX SWITCHER
Страница 8: ...9 1 SECTION 1 FEATURES OF THE SYSTEM 500 MATRIX SWITCHER ...
Страница 19: ...21 2 SECTION 2 DETAILED PRODUCT DESCRIPTION AND SELECTION ...
Страница 45: ...47 3 SECTION 3 INSTALLATION AND SYSTEM CONNECTIONS ...
Страница 61: ...65 4 SECTION 4 SOFTWARE SETUP ...
Страница 90: ...95 5 SECTION 5 OPERATING PROCEDURES ...
Страница 122: ...127 6 SECTION 6 TROUBLESHOOTING ...
Страница 126: ...131 7 SECTION 7 SPECIFICATIONS ...