65
■
Unit Address (System)
A unit address is a unique number to be assigned to
each PS·Data device. Each address of the system
devices must be unique to identify them when connect-
ing two or more PS·Data compatible devices. Numbers
"001" - "099" can be assigned to unit addresses for sys-
tem devices.
■
Unit Address (Controller)
The unit address (controller) is used to control a
PS·Data device connected to this unit. Assign a number
from "001" - "099" for a unit address.
■
Cascade
Select ON or OFF to determine whether or not to cas-
cade the units. Set to ON when using two or more units
for the cascade connection.
OFF:
Do not cascade the units
ON:
Cascade the units
■
Baud Rate
Select a communication speed for data transmission
with a connected device from the following:
2 400/4 800/9 600/19 200/38 400 bps
■
Data Bit
Data length for communication. Changing the setting
value is not possible.
8 bit
■
Parity
Select a method of error check for a transmission at
communication from the following:
NONE:
No parity check
EVEN:
Even parity
ODD:
Odd parity
■
Stop Bit
Select a stop bit from the following.
1/2 bit
■
Retry Timing
Select an interval for retrying when the data reception is
not confirmed from the following:
OFF/100 ms/200 ms/ 400 ms/1000 ms
■
Alarm Data
Select a method to notify of an event occurrence to the
connected controller from the following.
OFF:
Do not notify the controller.
0s:
Notify the controller every time an event is detected.
1s/5s:
Notify the controller when a specified time has
passed after detecting an event.
■
Camera Number Setup
Perform the settings for each camera channel to control
cameras using the PS·Data compatible controller.
The following window will be displayed when the
[SETUP] button is clicked.
Click the [
i
] button to assign camera numbers (001 -
255) to each camera channel. Click the [SET] button
after completing the settings, and close window by click-
ing the [
×
] button at the top right of the window.
Setup item
Содержание WJHD309 - DIGITAL DISK RECORDER