Configure event-related settings [Event setup] tab
Configure event-related settings such as the alarm output duration and buzzer duration.
■
Alarm action
Configure alarm-related items such as alarm output duration
and alarm auto reset.
[Output duration]
Select the output duration for the alarm signal output from
the terminal on the recorder's rear panel when an alarm
occurs. When "0 s" is selected, alarm signals will not be out-
put.
0 s/ 2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min
Ext.: Alarm output will continue until the alarm action is
reset. Refer to the Operating Instructions (PDF) for
further information about alarm reset.
Rec.: Output of the alarm signal will continue during
event recording.
Default:
2 s
[Buzzer duration]
Set the duration of the buzzer sound when an alarm occurs.
When "0 s" is selected, the buzzer will not sound.
0 s/ 2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min
Ext.: The buzzer will keep on sounding until the alarm
action is reset. Refer to the Operating Instructions
(PDF) for further information about alarm reset.
Rec.: The buzzer will keep on sounding during event
recording.
Default:
2 s
[Auto reset time]
Set the time for automatically resetting the alarm action.
2 s/ 5 s/ 10 s/ 20 s/ 30 s/ 1 min/ 3 min/ 5 min
Ext.: The alarm action will not automatically reset. Refer
to the operating instructions (PDF) for further infor-
mation about alarm reset.
Default:
Ext.
Note:
• If the time set for "Output duration" or "Buzzer duration"
is longer than that set for "Auto reset time", the time set
for "Auto reset time" will be applied.
[Message display]
Select whether or not to display a message on a PC con-
nected to a network when an alarm occurs.
On: Display a message.
Off: Does not display a message.
Default:
On
[Main monitor action]
While the main monitor is displaying the operation window,
select whether or not to switch to 1-screen display in associ-
ation with alarm occurrence.
On: Switch the monitor display in association with alarm
occurrence.
Off: Does not switch the monitor display.
Default:
Off
Note:
• The images from the camera selected for "Recording
camera" of "Advanced setup" are displayed on a
1-screen.
• The main monitor action will not be activated while
recorded images are being played back or the setup
menu is being displayed.
• When the auto reset time has passed, the monitor dis-
play will return to the previous status. (However, if a
mouse is operated while the main monitor action is
being activated, the monitor display will not return to the
previous status.)
■
Advanced event setup
Configure advanced settings for individual alarm types (ter-
minal alarm, camera site alarm, command alarm, and face
matching alarm). Clicking the [Advanced >] button for each
item will open the respective "Advanced setup" .