2

Do not insert your fi ngers or other objects into the unit, high speed rotating fan may cause injury.    

Do not sit or step on the unit, you may fall down accidentally.   

Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing.

Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or fi re.

Do not modify the wiring of outdoor unit for installation of other components (i.e. heater, etc). Overloaded wiring or wire connection points may 
cause electrical shock or fi re.

Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat above 370°C, fl ame, sparks, or other sources of ignition.
Else, it may explode and cause injury or death.

Do not add or replace refrigerant other than specifi ed type. It may cause product damage, burst and injury etc.

For electrical work, follow local wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. 
If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fi re.

Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fi re.

 

• The refrigerant cycle is completed inside the outdoor unit.

 

• Refrigerant piping work is not required.

 

• Pump down operation is not also required.

For refrigeration system work, install according to this installation instructions strictly. If installation is defective, it will cause water leakage, 
electrical shock or fi re.

Install at a strong and fi rm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the 
set will drop and cause injury.

Do not use joint cable for outdoor connection cable. Use specifi ed outdoor connection cable, refer to instruction 

4

 

CONNECT THE CABLE 

TO THE OUTDOOR UNIT

 and connect tightly for outdoor connection. Clamp the cable so that no external force will be acted on the terminal. If 

connection or fi xing is not perfect, it will cause heat up or fi re at the connection.

Wire routing must be properly arranged so that control board cover is fi xed properly. If control board cover is not fi xed perfectly, it will cause fi re 
or electrical shock.

After completion of installation, confi rm there is no leakage of refrigerant gas. It may lead to the risk of fi re or explosion when the refrigerant 
contacts with fi re.

Ventilate the room if there is refrigerant gas leakage during operation. Extinguish all fi re sources if present. It may lead to the risk of fi re or 
explosion when the refrigerant contacts with fi re.

Only use the supplied or specifi ed installation parts, else, it may cause unit vibrate loose, water leakage, electrical shock or fi re.

If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and information.

When installing electrical equipment at wooden building of metal lath or wire lath, in accordance with electrical facility standard, no electrical 
contact between equipment and building is allowed. Insulator must be installed in between.

Any work carried out on the outdoor unit after removing any panels which is secured by screws, must be carried out under the supervision of 
authorized dealer and licensed installation contractor.

Be aware that refrigerants may not contain an odour.

This unit must be properly earthed. The electrical earth must not be connected to a gas pipe, water pipe, the earth of lightening rod or a 
telephone. Otherwise there is a danger of electrical shock in the event of an insulation breakdown or electrical earth fault in the outdoor unit.

 CAUTION

Do not install the outdoor unit at place where leakage of fl ammable gas may occur. In case gas leaks and accumulates at surrounding of the 
unit, it may cause fi re.

Do not release refrigerant during repairing a refrigeration parts. Take care of the liquid refrigerant, it may cause frostbite.

Make sure the insulation of power supply cord does not contact hot part (i.e. refrigerant piping) to prevent from insulation failure (melt).

Do not touch the sharp aluminium fi n, sharp parts may cause injury.   

Select an installation location which is easy for maintenance.
Incorrect installation, service or repair of this outdoor unit may increase the risk of rupture and this may result in loss damage or injury and/or property.

Ensure the correct polarity is maintained throughout all wiring. Otherwise, it will cause electrical shock or fi re.

Installation work.
It may need two or more people to carry out the installation work. The weight of outdoor unit might cause injury if carried by one person.

Keep any required ventilation openings clear of obstruction.

Water piping in the occupied space shall be installed in such a way to protect against accidental damage in operation and service.

Precautions shall be taken to avoid excessive vibration or pulsation to water piping.

Protect the water piping from accidental rupture due to moving furniture or reconstruction activities.

 

• Must ensure the installation of water pipe-work shall be kept to a minimum. Avoid use dented pipe and do not allow acute bending.

 

• Must ensure that water pipe-work shall be protected from physical damage.

Содержание WH-WDG05LE5

Страница 1: ... be installed The caution items stated here must be followed because these important contents are related to safety The meaning of each indication used is as below Incorrect installation due to ignoring or negligence of the instruction will cause harm or damage and the seriousness is classified by the following indications Please leave the installation manual with the unit after installation WARNI...

Страница 2: ...eakage during operation Extinguish all fire sources if present It may lead to the risk of fire or explosion when the refrigerant contacts with fire Only use the supplied or specified installation parts else it may cause unit vibrate loose water leakage electrical shock or fire If there is any doubt about the installation procedure or operation always contact the authorized dealer for advice and in...

Страница 3: ...ations Must ensure mechanical connections be accessible for maintenance purposes In cases that require mechanical ventilation ventilation openings shall be kept clear of obstruction When disposal of the product do follow to the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel Any qualified person ...

Страница 4: ...charging recovering or purging the system That there is continuity of earth bonding At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If the faul...

Страница 5: ...re is ventilation available 9 Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position accordin...

Страница 6: ...ings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the re...

Страница 7: ...d this outdoor unit There must be no building openings windows doors light shafts cellar entrances escape hatches flat roof windows or ventilation openings in the protective zone There must be no ignition sources such as heat above 360 C sparks open flame plug sockets light switches lamps electrical switches or other permanent ignitions sources in the protective zone The protective zone must not e...

Страница 8: ...to tighten the hose at drain hose connector to prevent it from leaking Drain elbow 1 Rubber cap 2 After selecting the best location start installation according to Installation Diagram 1 When installing at roof please consider strong wind and earthquake Please fasten the installation stand firmly with bolt or nails 2 When installing to a concrete or solid surface use M10 or a W 3 8 bolts and nuts ...

Страница 9: ...ate Fig 4 1 2 Remove the terminal cover and cable gland cap Fig 4 2 3 Insert the cabtyre cable 1 Fig 4 3 4 4 Pulled in from the rear panel and inserted from the bottom of the electric controller BOX 4 Connect to terminal block Fig 4 5 5 Fasten the cable gland 2 Fig 4 4 6 Set the terminal cover 2 Fig 4 2 7 Set the front plate Fig 4 1 From Indoor unit Fig 4 3 Fig 4 1 Fig 4 2 Tightening torque 147 1 ...

Страница 10: ... 2 Remove the 3 screws Fasten the 3 screws Insert 4 claws WARNING This equipment must be properly earthed Terminals on the indoor unit 1 2 3 Colour of wires Terminals on the outdoor unit 1 2 3 Terminal screw Tightening torque cN m kgf cm M4 157 196 16 20 M5 196 245 20 25 1 2 3 Earth Wire must be longer than other wires for safety reason Screw Cable gland 5 mm or more gap between wires Indoor outdo...

Отзывы: